Description
With cast iron frame, flexible mounting, solid and whole feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications.
Standard | NEMA MG-1 |
---|---|
Frequency | 60//50 Hz |
Voltage | 230/460//380 V |
Number of poles | 6 |
Degree of Protection | IP55 |
Synchronous speed | 1200 rpm |
Output rating | 1 HP |
Mounting | W-6 |
Flange | C |
Terminal box¹ | Left position |
Enclosure | IC411 - TEFC |
Specifications
230/460 V 60 Hz 6P 380 V 50 Hz 6P IE3 400 V 50 Hz 6P IE3 415 V 50 Hz 6P IE3 380 V 50 Hz 6P IE2 400 V 50 Hz 6P IE2 415 V 50 Hz 6P IE2Electric Motors
Frame | 145TC |
---|---|
Output | 1 HP (0.75 kW) |
Number of Poles | 6 |
Frequency | 60 Hz |
Rated speed | 1160 rpm |
Slip | 3.33 % |
Rated voltage | 230/460 V |
Rated current | 3.46/1.73 A |
L. R. Amperes | 21.5/10.7 A |
LRC | 6.2x(Code K) |
No load current | 2.20/1.10 A |
Rated torque | 4.53 ft.lb |
Locked rotor torque | 260 % |
Breakdown torque | 300 % |
Locked rotor time | 50s (cold) 28s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.25 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 50.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 77.0 |
---|---|
75% | 82.0 |
100% | 82.5 |
Power factor
50% | 0.45 |
---|---|
75% | 0.57 |
100% | 0.66 |
Electric Motors
Frame | 145TC |
---|---|
Output | 0.75 HP (0.550 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 960 rpm |
Slip | 4.00 % |
Rated voltage | 380 V |
Rated current | 1.60 A |
L. R. Amperes | 9.28 A |
LRC | 5.8x(Code K) |
No load current | 1.05 A |
Rated torque | 4.10 ft.lb |
Locked rotor torque | 280 % |
Breakdown torque | 310 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 74.8 |
---|---|
75% | 78.4 |
100% | 79.3 |
Power factor
50% | 0.44 |
---|---|
75% | 0.57 |
100% | 0.66 |
Electric Motors
Frame | 145TC |
---|---|
Output | 0.75 HP (0.550 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 970 rpm |
Slip | 3.00 % |
Rated voltage | 400 V |
Rated current | 1.62 A |
L. R. Amperes | 9.88 A |
LRC | 6.1x(Code L) |
No load current | 1.15 A |
Rated torque | 4.06 ft.lb |
Locked rotor torque | 300 % |
Breakdown torque | 330 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 73.2 |
---|---|
75% | 77.5 |
100% | 78.9 |
Power factor
50% | 0.41 |
---|---|
75% | 0.53 |
100% | 0.62 |
Electric Motors
Frame | 145TC |
---|---|
Output | 0.75 HP (0.550 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 970 rpm |
Slip | 3.00 % |
Rated voltage | 415 V |
Rated current | 1.66 A |
L. R. Amperes | 10.5 A |
LRC | 6.3x(Code M) |
No load current | 1.25 A |
Rated torque | 4.06 ft.lb |
Locked rotor torque | 320 % |
Breakdown torque | 340 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 70.7 |
---|---|
75% | 75.8 |
100% | 77.9 |
Power factor
50% | 0.38 |
---|---|
75% | 0.50 |
100% | 0.59 |
Electric Motors
Frame | 145TC |
---|---|
Output | 1 HP (0.75 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 940 rpm |
Slip | 6.00 % |
Rated voltage | 380 V |
Rated current | 1.96 A |
L. R. Amperes | 9.41 A |
LRC | 4.8x(Code G) |
No load current | 1.05 A |
Rated torque | 5.59 ft.lb |
Locked rotor torque | 200 % |
Breakdown torque | 220 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 77.0 |
---|---|
75% | 80.0 |
100% | 78.5 |
Power factor
50% | 0.53 |
---|---|
75% | 0.66 |
100% | 0.74 |
Electric Motors
Frame | 145TC |
---|---|
Output | 1 HP (0.75 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 950 rpm |
Slip | 5.00 % |
Rated voltage | 400 V |
Rated current | 1.94 A |
L. R. Amperes | 10.1 A |
LRC | 5.2x(Code H) |
No load current | 1.15 A |
Rated torque | 5.53 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 260 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 75.5 |
---|---|
75% | 80.0 |
100% | 78.5 |
Power factor
50% | 0.49 |
---|---|
75% | 0.62 |
100% | 0.71 |
Electric Motors
Frame | 145TC |
---|---|
Output | 1 HP (0.75 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 950 rpm |
Slip | 5.00 % |
Rated voltage | 415 V |
Rated current | 1.95 A |
L. R. Amperes | 10.7 A |
LRC | 5.5x(Code J) |
No load current | 1.25 A |
Rated torque | 5.53 ft.lb |
Locked rotor torque | 250 % |
Breakdown torque | 280 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 0.1595 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | W-6 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 45.0 dB(A) |
Approx. weight³ | 53.5 lb |
Efficiency
50% | 74.0 |
---|---|
75% | 78.5 |
100% | 78.5 |
Power factor
50% | 0.46 |
---|---|
75% | 0.59 |
100% | 0.68 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Dip and Bake Polyester |
Main terminal box hole | NPT 3/4" |
Terminal Block | Without |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | RAL 5009 207A (ISO 12944 - C2) |
Grounding Lugs | Single |
Fan Cover material | Steel |
Tropicalized Painting | Without |
Fan material | Plastic |
Bearing cap | Yes- Bearing Cap |
Drip Cover | With |
Overload protector (phenolic) | Without overload protector |
Connection Cables Quantity | 9 |