WEG 00218ST3QIER145TC-W2 W22 IEEE 841 NEMA Premium Efficiency 2 HP 4P 145TC 3Ph 460 V 60 Hz IC411 - TEFC - Footless

WEGSKU: 00218ST3QIER145TC-W2

Dropship

Get it by Mon, Dec 23 - Sat, Dec 28

Price:
Sale price$850.08

Description

The W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1800 rpm
Output rating 2 HP
Mounting W-6
Flange C
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 145TC
Output 2 HP (1.5 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1750 rpm
Slip 2.78 %
Rated voltage 460 V
Rated current 2.79 A
L. R. Amperes 23.2 A
LRC 8.3x(Code L)
No load current 1.63 A
Rated torque 6.00 ft.lb
Locked rotor torque 270 %
Breakdown torque 320 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 51.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 85.5
75% 86.5
100% 86.5
Power factor
50% 0.57
75% 0.70
100% 0.78
Electric Motors
Frame 145TC
Output 1.5 HP (1.1 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 380 V
Rated current 2.57 A
L. R. Amperes 21.1 A
LRC 8.2x(Code L)
No load current 1.61 A
Rated torque 5.40 ft.lb
Locked rotor torque 290 %
Breakdown torque 330 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 84.0
75% 84.2
100% 84.5
Power factor
50% 0.55
75% 0.69
100% 0.77
Electric Motors
Frame 145TC
Output 1.5 HP (1.1 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 400 V
Rated current 2.57 A
L. R. Amperes 22.4 A
LRC 8.7x(Code M)
No load current 1.80 A
Rated torque 5.38 ft.lb
Locked rotor torque 320 %
Breakdown torque 380 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 82.0
75% 83.5
100% 84.5
Power factor
50% 0.50
75% 0.64
100% 0.73
Electric Motors
Frame 145TC
Output 1.5 HP (1.1 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 415 V
Rated current 2.56 A
L. R. Amperes 21.5 A
LRC 8.4x(Code M)
No load current 1.97 A
Rated torque 5.38 ft.lb
Locked rotor torque 350 %
Breakdown torque 409 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 81.4
75% 83.1
100% 84.1
Power factor
50% 0.47
75% 0.61
100% 0.71
Electric Motors
Frame 145TC
Output 2 HP (1.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1435 rpm
Slip 4.33 %
Rated voltage 380 V
Rated current 3.33 A
L. R. Amperes 20.0 A
LRC 6.0x(Code H)
No load current 1.61 A
Rated torque 7.32 ft.lb
Locked rotor torque 220 %
Breakdown torque 240 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 85.5
75% 84.0
100% 82.5
Power factor
50% 0.66
75% 0.78
100% 0.83
Electric Motors
Frame 145TC
Output 2 HP (1.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1440 rpm
Slip 4.00 %
Rated voltage 400 V
Rated current 3.22 A
L. R. Amperes 21.3 A
LRC 6.6x(Code J)
No load current 1.80 A
Rated torque 7.29 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 84.0
75% 84.0
100% 84.0
Power factor
50% 0.62
75% 0.74
100% 0.80
Electric Motors
Frame 145TC
Output 2 HP (1.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1450 rpm
Slip 3.33 %
Rated voltage 415 V
Rated current 3.14 A
L. R. Amperes 22.9 A
LRC 7.3x(Code K)
No load current 1.97 A
Rated torque 7.24 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.1561 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 59.2 lb
Efficiency
50% 84.0
75% 84.0
100% 84.0
Power factor
50% 0.60
75% 0.72
100% 0.79
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System Stainless Steel, at Drive end and Non-drive end
Main terminal box hole NPT 3/4"
Terminal Block Without
Shaft Locking Device Without
Drain Type T, Threaded
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting According to IEEE-841 (96h)
Joints Seal Molykote
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Drip Cover With
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 3
Downloads

You may also like

Recently viewed