These TEFC motors are built according to NEMA standard, and designed to operate with 100% of humidity in the most corrosive environments. All the line is certified for use with frequency inverter, and can operate in both the horizontal and vertical position. The Cooling Tower was tested according to the IEEE 112, method B, and it has efficiency values certified by UL (CSA C390). They ensure high efficiency levels with high torque, even at low speeds.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 575 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1200 rpm
Output rating 3 HP
Mounting F-2
Flange Without
Terminal box¹ Right position
Enclosure IC411 - TEFC
Electric Motors
Frame 213T
Output 3 HP (2.2 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1175 rpm
Slip 2.08 %
Rated voltage 575 V
Rated current 3.53 A
L. R. Amperes 24.7 A
LRC 7.0x(Code K)
No load current 2.20 A
Rated torque 13.4 ft.lb
Locked rotor torque 200 %
Breakdown torque 280 %
Locked rotor time 104s (cold) 58s (hot)
Moment of inertia (J) 1.20 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-2
Rotation¹ Both (CW and CCW)
Noise level² 55.0 dB(A)
Approx. weight³ 121 lb
Efficiency
50% 86.5
75% 88.5
100% 89.5
Power factor
50% 0.50
75% 0.63
100% 0.70
Features
Frame Material Cast Iron
Impregnation Method Double impregnation polyester
Space Heater Voltage 110-127/200-240 V
Main terminal box hole NPT 1"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Single
Fan Cover material Steel
Tropicalized Painting Complete (200h)
Joints Seal Permatex
Fan material Plastic
Bearing cap No-Without Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Features
Frame Material Cast Iron
Impregnation Method Double impregnation polyester
Space Heater Voltage 110-127/200-240 V
Main terminal box hole NPT 1"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Single
Fan Cover material Steel
Tropicalized Painting Complete (200h)
Joints Seal Permatex
Fan material Plastic
Bearing cap No-Without Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector