Description
The Rolled Steel motors line were developed for applications that demand performance, robustness and low weight integrated into a single product. The electrical and mechanical concept of the line make the motor present an optimum cost-benefit, providing reliability and energy savings.
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60//50 Hz |
| Voltage | 230/460//190-220/380-415 V |
| Number of poles | 4 |
| Synchronous speed | 1800 rpm |
| Output rating | 2 HP |
| Mounting | W-6 |
| Flange | C |
| Terminal box¹ | Left position |
| Enclosure | IC01 - ODP |
Electric Motors
| Frame | 143/5JM |
|---|---|
| Output | 2 HP (1.5 kW) |
| Number of Poles | 4 |
| Frequency | 60 Hz |
| Rated speed | 1740 rpm |
| Slip | 3.33 % |
| Rated voltage | 230/460 V |
| Rated current | 5.38/2.69 A |
| L. R. Amperes | 41.4/20.7 A |
| LRC | 7.7x(Code K) |
| No load current | 2.75/1.38 A |
| Rated torque | 6.04 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 320 % |
| Locked rotor time | 30s (cold) 17s (hot) |
| Moment of inertia (J) | 0.1168 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Temperature rise | 80 K |
| Service factor | 1.15 (1.00 @ 208V) |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Enclosure | IC01 - ODP |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 52.0 dB(A) |
| Approx. weight³ | 40.9 lb |
Efficiency
| 50% | 85.5 |
|---|---|
| 75% | 86.5 |
| 100% | 86.5 |
Power factor
| 50% | 0.61 |
|---|---|
| 75% | 0.74 |
| 100% | 0.81 |
Electric Motors
| Frame | 143/5JM |
|---|---|
| Output | 2 HP (1.5 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1410 rpm |
| Slip | 6.00 % |
| Rated voltage | 190-220/380 V |
| Rated current | 6.52-5.63/3.26 A |
| L. R. Amperes | 36.5-31.5/18.3 A |
| LRC | 5.6x(Code G) |
| No load current | 2.70-2.33/1.35 A |
| Rated torque | 7.45 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 229 % |
| Locked rotor time | 0s (cold) 0s (hot) |
| Moment of inertia (J) | 0.1168 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 (1.00 @ 208V) |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Enclosure | IC01 - ODP |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 49.0 dB(A) |
| Approx. weight³ | 40.9 lb |
Efficiency
| 50% | 85.9 |
|---|---|
| 75% | 85.0 |
| 100% | 82.2 |
Power factor
| 50% | 0.69 |
|---|---|
| 75% | 0.80 |
| 100% | 0.85 |
Electric Motors
| Frame | 143/5JM |
|---|---|
| Output | 2 HP (1.5 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1430 rpm |
| Slip | 4.67 % |
| Rated voltage | 415 V |
| Rated current | 3.07 A |
| L. R. Amperes | 20.6 A |
| LRC | 6.7x(Code J) |
| No load current | 1.63 A |
| Rated torque | 7.34 ft.lb |
| Locked rotor torque | 250 % |
| Breakdown torque | 280 % |
| Locked rotor time | 0s (cold) 0s (hot) |
| Moment of inertia (J) | 0.1168 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 (1.00 @ 208V) |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Enclosure | IC01 - ODP |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 49.0 dB(A) |
| Approx. weight³ | 40.9 lb |
Efficiency
| 50% | 84.6 |
|---|---|
| 75% | 85.2 |
| 100% | 83.8 |
Power factor
| 50% | 0.61 |
|---|---|
| 75% | 0.74 |
| 100% | 0.81 |
Features
| Frame Material | Rolled Steel |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Main terminal box hole | 1.118" |
| Terminal Block | Without |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | Munsell N 1 - Matte 207N (ISO 12944 - C2) |
| Grounding Lugs | Single |
| Fan Cover material | Without Fan Cover |
| Tropicalized Painting | Without |
| Fan material | Without fan |
| Bearing cap | Yes- Bearing Cap |
| Bolt Material | Carbon Steel |
| Balancing Method | 1/2 Key |
| Drip Cover | With |
| Resilient Base | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 9 |