WEG E25018ET3YAX355MLF3W W22Xec IE3 250 kW 4P 355M/L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E25018ET3YAX355MLF3W

GTIN :

MPN :

Dropship

Price:
Sale price$83,195.00

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 250 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 355M/L
Output 250 kW (340 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1488 rpm
Slip 0.80 %
Rated voltage 380/660 V
Rated current 460/265 A
L. R. Amperes 3358/1933 A
LRC 7.3
No load current 135/77.7 A
Rated torque 1180 ft.lb
Locked rotor torque 200 %
Breakdown torque 210 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 183 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 3419 lb
Efficiency
50% 95.8
75% 96.0
100% 96.0
Power factor
50% 0.77
75% 0.84
100% 0.86
Electric Motors
Frame 355M/L
Output 250 kW (340 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 400/690 V
Rated current 442/256 A
L. R. Amperes 3227/1870 A
LRC 7.3
No load current 148/85.8 A
Rated torque 1180 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 183 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 3419 lb
Efficiency
50% 95.9
75% 96.0
100% 96.0
Power factor
50% 0.74
75% 0.82
100% 0.85
Electric Motors
Frame 355M/L
Output 250 kW (340 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1491 rpm
Slip 0.60 %
Rated voltage 415 V
Rated current 431 A
L. R. Amperes 3146 A
LRC 7.3
No load current 160 A
Rated torque 1180 ft.lb
Locked rotor torque 250 %
Breakdown torque 260 %
Locked rotor time 39s (cold) 22s (hot)
Moment of inertia (J) 183 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 3419 lb
Efficiency
50% 95.8
75% 96.0
100% 96.0
Power factor
50% 0.71
75% 0.80
100% 0.84
Electric Motors
Frame 355M/L
Output 250 kW (340 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1791 rpm
Slip 0.50 %
Rated voltage 460 V
Rated current 384 A
L. R. Amperes 3034 A
LRC 7.9
No load current 137 A
Rated torque 984 ft.lb
Locked rotor torque 270 %
Breakdown torque 270 %
Locked rotor time 46s (cold) 26s (hot)
Moment of inertia (J) 183 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 3419 lb
Efficiency
50% 95.2
75% 96.2
100% 96.2
Power factor
50% 0.72
75% 0.81
100% 0.85
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Aluminum
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed