The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 200 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 315L
Output 200 kW (270 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1486 rpm
Slip 0.93 %
Rated voltage 380/660 V
Rated current 360/207 A
L. R. Amperes 2160/1244 A
LRC 6.0
No load current 99.0/57.0 A
Rated torque 949 ft.lb
Locked rotor torque 210 %
Breakdown torque 210 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 113 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 2935 lb
Efficiency
50% 96.1
75% 96.2
100% 96.0
Power factor
50% 0.80
75% 0.86
100% 0.88
Electric Motors
Frame 315L
Output 200 kW (270 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1488 rpm
Slip 0.80 %
Rated voltage 400/690 V
Rated current 346/201 A
L. R. Amperes 2318/1344 A
LRC 6.7
No load current 106/61.4 A
Rated torque 947 ft.lb
Locked rotor torque 240 %
Breakdown torque 240 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 113 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 2935 lb
Efficiency
50% 96.0
75% 96.3
100% 96.0
Power factor
50% 0.78
75% 0.85
100% 0.87
Electric Motors
Frame 315L
Output 200 kW (270 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1489 rpm
Slip 0.73 %
Rated voltage 415 V
Rated current 333 A
L. R. Amperes 2398 A
LRC 7.2
No load current 112 A
Rated torque 947 ft.lb
Locked rotor torque 250 %
Breakdown torque 260 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 113 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 2935 lb
Efficiency
50% 95.9
75% 96.3
100% 96.1
Power factor
50% 0.76
75% 0.83
100% 0.87
Electric Motors
Frame 315L
Output 200 kW (270 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1790 rpm
Slip 0.56 %
Rated voltage 460 V
Rated current 300 A
L. R. Amperes 2280 A
LRC 7.6
No load current 100 A
Rated torque 787 ft.lb
Locked rotor torque 270 %
Breakdown torque 260 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 113 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2935 lb
Efficiency
50% 95.5
75% 96.2
100% 96.2
Power factor
50% 0.76
75% 0.84
100% 0.87
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Aluminum
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6