WEG E16036ET3YAX315SMF3W W22Xec IE3 160 kW 2P 315S/M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E16036ET3YAX315SMF3W

Drop-Ship

Price:
Sale price$39,549.51

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 160 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 315S/M
Output 160 kW (220 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 380/660 V
Rated current 286/165 A
L. R. Amperes 2002/1153 A
LRC 7.0
No load current 72.0/41.5 A
Rated torque 379 ft.lb
Locked rotor torque 200 %
Breakdown torque 260 %
Locked rotor time 50s (cold) 28s (hot)
Moment of inertia (J) 53.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2282 lb
Efficiency
50% 95.0
75% 95.6
100% 95.6
Power factor
50% 0.82
75% 0.87
100% 0.89
Electric Motors
Frame 315S/M
Output 160 kW (220 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2980 rpm
Slip 0.67 %
Rated voltage 400/690 V
Rated current 275/159 A
L. R. Amperes 2063/1196 A
LRC 7.5
No load current 79.0/45.8 A
Rated torque 378 ft.lb
Locked rotor torque 220 %
Breakdown torque 290 %
Locked rotor time 50s (cold) 28s (hot)
Moment of inertia (J) 53.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2282 lb
Efficiency
50% 94.8
75% 95.6
100% 95.6
Power factor
50% 0.79
75% 0.86
100% 0.88
Electric Motors
Frame 315S/M
Output 160 kW (220 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2980 rpm
Slip 0.67 %
Rated voltage 415 V
Rated current 268 A
L. R. Amperes 2144 A
LRC 8.0
No load current 84.0 A
Rated torque 378 ft.lb
Locked rotor torque 229 %
Breakdown torque 310 %
Locked rotor time 50s (cold) 28s (hot)
Moment of inertia (J) 53.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 2282 lb
Efficiency
50% 94.5
75% 95.6
100% 95.6
Power factor
50% 0.77
75% 0.84
100% 0.87
Electric Motors
Frame 315S/M
Output 160 kW (220 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3582 rpm
Slip 0.50 %
Rated voltage 460 V
Rated current 239 A
L. R. Amperes 2032 A
LRC 8.5
No load current 74.0 A
Rated torque 315 ft.lb
Locked rotor torque 250 %
Breakdown torque 320 %
Locked rotor time 50s (cold) 28s (hot)
Moment of inertia (J) 53.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 2282 lb
Efficiency
50% 93.8
75% 95.1
100% 95.4
Power factor
50% 0.78
75% 0.85
100% 0.88
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed