WEG E16012ET3YAX355MLF3W W22Xec IE3 160 kW 6P 355M/L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E16012ET3YAX355MLF3W

Drop-Ship

Price:
Sale price$66,943.80

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 160 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 355M/L
Output 160 kW (220 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 992 rpm
Slip 0.80 %
Rated voltage 380/660 V
Rated current 313/180 A
L. R. Amperes 1565/901 A
LRC 5.0
No load current 107/61.6 A
Rated torque 1140 ft.lb
Locked rotor torque 160 %
Breakdown torque 190 %
Locked rotor time 59s (cold) 33s (hot)
Moment of inertia (J) 209 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 3309 lb
Efficiency
50% 95.0
75% 95.8
100% 95.8
Power factor
50% 0.67
75% 0.77
100% 0.81
Electric Motors
Frame 355M/L
Output 160 kW (220 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 993 rpm
Slip 0.70 %
Rated voltage 400/690 V
Rated current 305/177 A
L. R. Amperes 1678/972 A
LRC 5.5
No load current 114/66.1 A
Rated torque 1140 ft.lb
Locked rotor torque 180 %
Breakdown torque 210 %
Locked rotor time 59s (cold) 33s (hot)
Moment of inertia (J) 209 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 3309 lb
Efficiency
50% 94.9
75% 95.6
100% 95.8
Power factor
50% 0.63
75% 0.74
100% 0.79
Electric Motors
Frame 355M/L
Output 160 kW (220 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 993 rpm
Slip 0.70 %
Rated voltage 415 V
Rated current 302 A
L. R. Amperes 1812 A
LRC 6.0
No load current 121 A
Rated torque 1140 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 59s (cold) 33s (hot)
Moment of inertia (J) 209 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 73.0 dB(A)
Approx. weight³ 3309 lb
Efficiency
50% 95.0
75% 95.8
100% 95.8
Power factor
50% 0.60
75% 0.72
100% 0.77
Electric Motors
Frame 355M/L
Output 160 kW (220 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1195 rpm
Slip 0.42 %
Rated voltage 460 V
Rated current 269 A
L. R. Amperes 1775 A
LRC 6.6
No load current 107 A
Rated torque 944 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 59s (cold) 33s (hot)
Moment of inertia (J) 209 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 3309 lb
Efficiency
50% 94.6
75% 95.8
100% 95.8
Power factor
50% 0.61
75% 0.72
100% 0.78
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Aluminum
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like