WEG E09012ET3YAX315SMF3W W22Xec IE3 90 kW 6P 315S/M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E09012ET3YAX315SMF3W

Drop-Ship

Price:
Sale price$27,549.83

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 90 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 315S/M
Output 90 kW (125 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 380/660 V
Rated current 175/101 A
L. R. Amperes 963/554 A
LRC 5.5
No load current 73.2/42.1 A
Rated torque 641 ft.lb
Locked rotor torque 180 %
Breakdown torque 229 %
Locked rotor time 57s (cold) 32s (hot)
Moment of inertia (J) 129 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2626 lb
Efficiency
50% 95.0
75% 95.1
100% 95.1
Power factor
50% 0.68
75% 0.77
100% 0.82
Electric Motors
Frame 315S/M
Output 90 kW (125 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 991 rpm
Slip 0.90 %
Rated voltage 400/690 V
Rated current 171/99.1 A
L. R. Amperes 1094/634 A
LRC 6.4
No load current 80.6/46.7 A
Rated torque 640 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 52s (cold) 29s (hot)
Moment of inertia (J) 129 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2626 lb
Efficiency
50% 94.5
75% 95.1
100% 95.1
Power factor
50% 0.64
75% 0.75
100% 0.80
Electric Motors
Frame 315S/M
Output 90 kW (125 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 992 rpm
Slip 0.80 %
Rated voltage 415 V
Rated current 169 A
L. R. Amperes 1099 A
LRC 6.5
No load current 88.1 A
Rated torque 639 ft.lb
Locked rotor torque 220 %
Breakdown torque 270 %
Locked rotor time 46s (cold) 26s (hot)
Moment of inertia (J) 129 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2626 lb
Efficiency
50% 94.0
75% 94.5
100% 95.1
Power factor
50% 0.60
75% 0.73
100% 0.78
Electric Motors
Frame 315S/M
Output 90 kW (125 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1193 rpm
Slip 0.58 %
Rated voltage 460 V
Rated current 150 A
L. R. Amperes 1035 A
LRC 6.9
No load current 73.8 A
Rated torque 532 ft.lb
Locked rotor torque 229 %
Breakdown torque 280 %
Locked rotor time 64s (cold) 36s (hot)
Moment of inertia (J) 129 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2626 lb
Efficiency
50% 94.7
75% 95.4
100% 95.4
Power factor
50% 0.60
75% 0.73
100% 0.79
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads