WEG E04518ET3YAX225SMF3W W22Xec IE3 45 kW 4P 225S/M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E04518ET3YAX225SMF3W

Drop-Ship

Price:
Sale price$11,866.48

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 45 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 225S/M
Output 45 kW (60 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 380/660 V
Rated current 86.4/49.7 A
L. R. Amperes 579/333 A
LRC 6.7
No load current 33.0/19.0 A
Rated torque 215 ft.lb
Locked rotor torque 240 %
Breakdown torque 280 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 16.0 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 93.8
75% 94.0
100% 94.2
Power factor
50% 0.70
75% 0.80
100% 0.84
Electric Motors
Frame 225S/M
Output 45 kW (60 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 400/690 V
Rated current 84.1/48.8 A
L. R. Amperes 631/366 A
LRC 7.5
No load current 37.0/21.4 A
Rated torque 214 ft.lb
Locked rotor torque 280 %
Breakdown torque 310 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 16.0 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 93.7
75% 94.1
100% 94.2
Power factor
50% 0.66
75% 0.77
100% 0.82
Electric Motors
Frame 225S/M
Output 45 kW (60 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 83.1 A
L. R. Amperes 656 A
LRC 7.9
No load current 40.0 A
Rated torque 214 ft.lb
Locked rotor torque 300 %
Breakdown torque 340 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 16.0 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 93.0
75% 94.1
100% 94.2
Power factor
50% 0.62
75% 0.75
100% 0.80
Electric Motors
Frame 225S/M
Output 45 kW (60 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1783 rpm
Slip 0.94 %
Rated voltage 460 V
Rated current 73.4 A
L. R. Amperes 631 A
LRC 8.6
No load current 34.0 A
Rated torque 178 ft.lb
Locked rotor torque 320 %
Breakdown torque 360 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 16.0 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 93.0
75% 94.5
100% 95.0
Power factor
50% 0.64
75% 0.75
100% 0.81
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like