WEG E03036ET3YAX200LF3-W W22Xec IE3 30 kW 2P 200L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E03036ET3YAX200LF3-W

Drop-Ship

Price:
Sale price$7,646.88

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 30 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 380/660 V
Rated current 56.2/32.4 A
L. R. Amperes 405/233 A
LRC 7.2
No load current 17.0/9.79 A
Rated torque 71.3 ft.lb
Locked rotor torque 300 %
Breakdown torque 290 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 4.04 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 584 lb
Efficiency
50% 92.6
75% 93.2
100% 93.3
Power factor
50% 0.75
75% 0.83
100% 0.87
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 400/690 V
Rated current 54.6/31.7 A
L. R. Amperes 426/247 A
LRC 7.8
No load current 19.0/11.0 A
Rated torque 71.2 ft.lb
Locked rotor torque 330 %
Breakdown torque 320 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 4.04 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 584 lb
Efficiency
50% 92.2
75% 93.2
100% 93.3
Power factor
50% 0.69
75% 0.80
100% 0.85
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 415 V
Rated current 53.9 A
L. R. Amperes 447 A
LRC 8.3
No load current 20.0 A
Rated torque 71.1 ft.lb
Locked rotor torque 360 %
Breakdown torque 350 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 4.04 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 584 lb
Efficiency
50% 91.8
75% 93.0
100% 93.3
Power factor
50% 0.64
75% 0.77
100% 0.83
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3575 rpm
Slip 0.69 %
Rated voltage 460 V
Rated current 48.2 A
L. R. Amperes 424 A
LRC 8.8
No load current 18.0 A
Rated torque 59.1 ft.lb
Locked rotor torque 390 %
Breakdown torque 370 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 4.04 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 584 lb
Efficiency
50% 90.8
75% 92.6
100% 93.0
Power factor
50% 0.69
75% 0.79
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed