WEG E03018ET3YAX200LF3-W W22Xec IE3 30 kW 4P 200L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E03018ET3YAX200LF3-W

Drop-Ship

Price:
Sale price$7,703.08

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 30 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 380/660 V
Rated current 58.0/33.4 A
L. R. Amperes 423/244 A
LRC 7.3
No load current 24.5/14.1 A
Rated torque 143 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 7.60 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 575 lb
Efficiency
50% 93.4
75% 93.6
100% 93.6
Power factor
50% 0.68
75% 0.79
100% 0.84
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 400/690 V
Rated current 57.1/33.1 A
L. R. Amperes 428/248 A
LRC 7.5
No load current 27.0/15.7 A
Rated torque 143 ft.lb
Locked rotor torque 280 %
Breakdown torque 310 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 7.60 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 575 lb
Efficiency
50% 92.9
75% 93.6
100% 93.6
Power factor
50% 0.63
75% 0.75
100% 0.81
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 56.4 A
L. R. Amperes 440 A
LRC 7.8
No load current 30.0 A
Rated torque 143 ft.lb
Locked rotor torque 300 %
Breakdown torque 340 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 7.60 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 575 lb
Efficiency
50% 92.3
75% 93.3
100% 93.6
Power factor
50% 0.59
75% 0.72
100% 0.79
Electric Motors
Frame 200L
Output 30 kW (40 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1785 rpm
Slip 0.83 %
Rated voltage 460 V
Rated current 50.0 A
L. R. Amperes 415 A
LRC 8.3
No load current 25.5 A
Rated torque 118 ft.lb
Locked rotor torque 340 %
Breakdown torque 350 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 7.60 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 575 lb
Efficiency
50% 92.6
75% 93.7
100% 94.1
Power factor
50% 0.62
75% 0.74
100% 0.80
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed