WEG E02236ET3YAX180MF3-W W22Xec IE3 22 kW 2P 180M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E02236ET3YAX180MF3-W

Drop-Ship

Price:
Sale price$5,229.84

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 22 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 180M
Output 22 kW (30 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 380/660 V
Rated current 41.4/23.8 A
L. R. Amperes 344/198 A
LRC 8.3
No load current 14.0/8.06 A
Rated torque 52.5 ft.lb
Locked rotor torque 290 %
Breakdown torque 290 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 2.30 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 398 lb
Efficiency
50% 92.2
75% 92.7
100% 92.7
Power factor
50% 0.74
75% 0.83
100% 0.87
Electric Motors
Frame 180M
Output 22 kW (30 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 400/690 V
Rated current 39.8/23.1 A
L. R. Amperes 330/192 A
LRC 8.3
No load current 15.0/8.70 A
Rated torque 52.4 ft.lb
Locked rotor torque 320 %
Breakdown torque 320 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 2.30 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 398 lb
Efficiency
50% 92.0
75% 92.7
100% 92.7
Power factor
50% 0.69
75% 0.80
100% 0.86
Electric Motors
Frame 180M
Output 22 kW (30 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 415 V
Rated current 39.3 A
L. R. Amperes 326 A
LRC 8.3
No load current 17.0 A
Rated torque 52.3 ft.lb
Locked rotor torque 340 %
Breakdown torque 340 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 2.30 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 398 lb
Efficiency
50% 91.5
75% 92.5
100% 92.7
Power factor
50% 0.66
75% 0.78
100% 0.84
Electric Motors
Frame 180M
Output 22 kW (30 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3565 rpm
Slip 0.97 %
Rated voltage 460 V
Rated current 35.6 A
L. R. Amperes 313 A
LRC 8.8
No load current 14.5 A
Rated torque 43.5 ft.lb
Locked rotor torque 380 %
Breakdown torque 370 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 2.30 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 398 lb
Efficiency
50% 91.6
75% 92.2
100% 92.4
Power factor
50% 0.68
75% 0.79
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6