Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 18.5 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 200L
Output 18.5 kW (25 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 380/660 V
Rated current 37.4/21.5 A
L. R. Amperes 224/129 A
LRC 6.0
No load current 15.5/8.92 A
Rated torque 134 ft.lb
Locked rotor torque 200 %
Breakdown torque 220 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 8.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 60.0 dB(A)
Approx. weight³ 496 lb
Efficiency
50% 91.0
75% 91.7
100% 91.7
Power factor
50% 0.68
75% 0.78
100% 0.82
Electric Motors
Frame 200L
Output 18.5 kW (25 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 400/690 V
Rated current 36.3/21.0 A
L. R. Amperes 229/133 A
LRC 6.3
No load current 17.0/9.86 A
Rated torque 133 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 8.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 60.0 dB(A)
Approx. weight³ 496 lb
Efficiency
50% 91.0
75% 91.7
100% 91.9
Power factor
50% 0.63
75% 0.70
100% 0.80
Electric Motors
Frame 200L
Output 18.5 kW (25 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 36.0 A
L. R. Amperes 238 A
LRC 6.6
No load current 19.0 A
Rated torque 133 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 8.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 60.0 dB(A)
Approx. weight³ 496 lb
Efficiency
50% 90.3
75% 91.4
100% 91.7
Power factor
50% 0.59
75% 0.72
100% 0.78
Electric Motors
Frame 200L
Output 18.5 kW (25 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1182 rpm
Slip 1.50 %
Rated voltage 460 V
Rated current 32.0 A
L. R. Amperes 224 A
LRC 7.0
No load current 16.5 A
Rated torque 110 ft.lb
Locked rotor torque 260 %
Breakdown torque 300 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 8.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 496 lb
Efficiency
50% 90.9
75% 92.1
100% 93.0
Power factor
50% 0.61
75% 0.73
100% 0.78
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like