WEG E01536ET3YAX160MF3-W W22Xec IE3 15 kW 2P 160M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01536ET3YAX160MF3-W

Drop-Ship

Price:
Sale price$3,457.30

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 15 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160M
Output 15 kW (20 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 380/660 V
Rated current 28.5/16.4 A
L. R. Amperes 222/128 A
LRC 7.8
No load current 10.0/5.76 A
Rated torque 35.9 ft.lb
Locked rotor torque 250 %
Breakdown torque 320 %
Locked rotor time 14s (cold) 8s (hot)
Moment of inertia (J) 1.31 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 91.0
75% 91.6
100% 91.9
Power factor
50% 0.72
75% 0.82
100% 0.87
Electric Motors
Frame 160M
Output 15 kW (20 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2950 rpm
Slip 1.67 %
Rated voltage 400/690 V
Rated current 27.7/16.1 A
L. R. Amperes 230/133 A
LRC 8.3
No load current 11.0/6.38 A
Rated torque 35.8 ft.lb
Locked rotor torque 280 %
Breakdown torque 360 %
Locked rotor time 14s (cold) 8s (hot)
Moment of inertia (J) 1.31 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 90.9
75% 91.8
100% 92.0
Power factor
50% 0.67
75% 0.79
100% 0.85
Electric Motors
Frame 160M
Output 15 kW (20 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 27.7 A
L. R. Amperes 244 A
LRC 8.8
No load current 12.0 A
Rated torque 35.8 ft.lb
Locked rotor torque 300 %
Breakdown torque 390 %
Locked rotor time 14s (cold) 8s (hot)
Moment of inertia (J) 1.31 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 90.3
75% 91.6
100% 91.9
Power factor
50% 0.63
75% 0.76
100% 0.82
Electric Motors
Frame 160M
Output 15 kW (20 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3560 rpm
Slip 1.11 %
Rated voltage 460 V
Rated current 24.7 A
L. R. Amperes 222 A
LRC 9.0
No load current 11.0 A
Rated torque 29.7 ft.lb
Locked rotor torque 340 %
Breakdown torque 430 %
Locked rotor time 14s (cold) 8s (hot)
Moment of inertia (J) 1.31 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 89.7
75% 91.5
100% 91.7
Power factor
50% 0.66
75% 0.78
100% 0.83
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like