WEG E01518ET3YAX160LF3-W W22Xec IE3 15 kW 4P 160L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01518ET3YAX160LF3-W

Drop-Ship

Price:
Sale price$3,615.93

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 15 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 380/660 V
Rated current 29.1/16.8 A
L. R. Amperes 192/111 A
LRC 6.6
No load current 12.0/6.91 A
Rated torque 72.2 ft.lb
Locked rotor torque 240 %
Breakdown torque 270 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 3.64 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 330 lb
Efficiency
50% 92.1
75% 92.4
100% 92.1
Power factor
50% 0.70
75% 0.80
100% 0.85
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 400/690 V
Rated current 28.3/16.4 A
L. R. Amperes 198/115 A
LRC 7.0
No load current 13.0/7.54 A
Rated torque 71.9 ft.lb
Locked rotor torque 270 %
Breakdown torque 300 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 3.64 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 330 lb
Efficiency
50% 92.0
75% 92.5
100% 92.3
Power factor
50% 0.66
75% 0.77
100% 0.83
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 415 V
Rated current 28.0 A
L. R. Amperes 207 A
LRC 7.4
No load current 14.0 A
Rated torque 71.7 ft.lb
Locked rotor torque 300 %
Breakdown torque 320 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 3.64 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 330 lb
Efficiency
50% 91.4
75% 92.3
100% 92.1
Power factor
50% 0.62
75% 0.75
100% 0.81
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1776 rpm
Slip 1.33 %
Rated voltage 460 V
Rated current 25.0 A
L. R. Amperes 200 A
LRC 8.0
No load current 12.5 A
Rated torque 59.5 ft.lb
Locked rotor torque 320 %
Breakdown torque 340 %
Locked rotor time 34s (cold) 19s (hot)
Moment of inertia (J) 3.64 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 330 lb
Efficiency
50% 92.0
75% 92.9
100% 93.0
Power factor
50% 0.63
75% 0.75
100% 0.81
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like