WEG E01518EP3Y160LF3-W22 W22 IE2 15 kW 4P 160L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01518EP3Y160LF3-W22

Drop-Ship

Price:
Sale price$1,386.00

Description

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 15 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 380/660 V
Rated current 29.6/17.0 A
L. R. Amperes 178/102 A
LRC 6.0
No load current 12.6/7.25 A
Rated torque 71.9 ft.lb
Locked rotor torque 200 %
Breakdown torque 250 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 2.98 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 332 lb
Efficiency
50% 90.8
75% 90.9
100% 90.6
Power factor
50% 0.70
75% 0.79
100% 0.85
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400/690 V
Rated current 28.8/16.7 A
L. R. Amperes 179/104 A
LRC 6.2
No load current 13.7/7.94 A
Rated torque 71.7 ft.lb
Locked rotor torque 229 %
Breakdown torque 280 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 2.98 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 332 lb
Efficiency
50% 90.5
75% 90.8
100% 90.7
Power factor
50% 0.66
75% 0.76
100% 0.83
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 415 V
Rated current 28.4 A
L. R. Amperes 182 A
LRC 6.4
No load current 14.7 A
Rated torque 71.7 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 14s (cold) 8s (hot)
Moment of inertia (J) 2.98 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 332 lb
Efficiency
50% 90.0
75% 90.7
100% 90.8
Power factor
50% 0.63
75% 0.73
100% 0.81
Electric Motors
Frame 160L
Output 15 kW (20 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1775 rpm
Slip 1.39 %
Rated voltage 460 V
Rated current 25.3 A
L. R. Amperes 172 A
LRC 6.8
No load current 12.8 A
Rated torque 59.6 ft.lb
Locked rotor torque 260 %
Breakdown torque 320 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 2.98 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 332 lb
Efficiency
50% 90.2
75% 91.0
100% 91.7
Power factor
50% 0.62
75% 0.75
100% 0.81
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Single
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 155°C
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads