WEG E01512XP3YAX180LF3-W W22Xdb IE2 15 kW 6P 180M/L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01512XP3YAX180LF3-W

Drop-Ship

Price:
Sale price$4,955.73

Description

The W22Xdb line is an evolution in the market of classified area products offering high efficiency levels, energy saving, low operational costs, extended lifetime, low maintenance and assured safety.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP56
Synchronous speed 1000 rpm
Output rating 15 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 180M/L
Output 15 kW (20 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 380/660 V
Rated current 29.9/17.2 A
L. R. Amperes 209/121 A
LRC 7.0
No load current 11.5/6.62 A
Rated torque 109 ft.lb
Locked rotor torque 220 %
Breakdown torque 270 %
Locked rotor time 12s (cold) 7s (hot)
Moment of inertia (J) 6.09 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 543 lb
Efficiency
50% 90.6
75% 90.4
100% 89.7
Power factor
50% 0.70
75% 0.80
100% 0.85
Electric Motors
Frame 180M/L
Output 15 kW (20 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 400/690 V
Rated current 28.5/16.5 A
L. R. Amperes 214/124 A
LRC 7.5
No load current 12.5/7.25 A
Rated torque 108 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 12s (cold) 7s (hot)
Moment of inertia (J) 6.09 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 543 lb
Efficiency
50% 90.3
75% 90.5
100% 90.3
Power factor
50% 0.69
75% 0.79
100% 0.84
Electric Motors
Frame 180M/L
Output 15 kW (20 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 978 rpm
Slip 2.20 %
Rated voltage 415 V
Rated current 27.8 A
L. R. Amperes 222 A
LRC 8.0
No load current 13.5 A
Rated torque 108 ft.lb
Locked rotor torque 280 %
Breakdown torque 330 %
Locked rotor time 12s (cold) 7s (hot)
Moment of inertia (J) 6.09 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 543 lb
Efficiency
50% 89.9
75% 90.5
100% 90.6
Power factor
50% 0.65
75% 0.77
100% 0.83
Electric Motors
Frame 180M/L
Output 15 kW (20 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1180 rpm
Slip 1.67 %
Rated voltage 460 V
Rated current 24.9 A
L. R. Amperes 224 A
LRC 9.0
No load current 11.7 A
Rated torque 89.6 ft.lb
Locked rotor torque 300 %
Breakdown torque 350 %
Locked rotor time 12s (cold) 7s (hot)
Moment of inertia (J) 6.09 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP56
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 543 lb
Efficiency
50% 90.2
75% 91.0
100% 91.0
Power factor
50% 0.65
75% 0.77
100% 0.83
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Space Heater Voltage 200 - 240 V
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C4)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Joints Seal Lumomoly
Fan material Aluminum
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Winding thermal protection Thermistor - 2 wires 1 per phase 150°C
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like