WEG E01136ET3YAX160MF3-W W22Xec IE3 11 kW 2P 160M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01136ET3YAX160MF3-W

Drop-Ship

Price:
Sale price$3,205.51

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 11 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160M
Output 11 kW (15 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 380/660 V
Rated current 21.3/12.3 A
L. R. Amperes 168/96.9 A
LRC 7.9
No load current 9.10/5.24 A
Rated torque 26.2 ft.lb
Locked rotor torque 270 %
Breakdown torque 350 %
Locked rotor time 19s (cold) 11s (hot)
Moment of inertia (J) 1.14 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 270 lb
Efficiency
50% 90.0
75% 91.2
100% 91.2
Power factor
50% 0.69
75% 0.80
100% 0.86
Electric Motors
Frame 160M
Output 11 kW (15 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 400/690 V
Rated current 21.0/12.2 A
L. R. Amperes 179/103 A
LRC 8.5
No load current 10.1/5.86 A
Rated torque 26.2 ft.lb
Locked rotor torque 310 %
Breakdown torque 300 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 1.14 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 270 lb
Efficiency
50% 89.0
75% 91.0
100% 91.2
Power factor
50% 0.65
75% 0.77
100% 0.83
Electric Motors
Frame 160M
Output 11 kW (15 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 20.7 A
L. R. Amperes 188 A
LRC 9.1
No load current 11.0 A
Rated torque 26.2 ft.lb
Locked rotor torque 330 %
Breakdown torque 420 %
Locked rotor time 16s (cold) 9s (hot)
Moment of inertia (J) 1.14 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 270 lb
Efficiency
50% 88.0
75% 90.0
100% 91.2
Power factor
50% 0.60
75% 0.73
100% 0.81
Electric Motors
Frame 160M
Output 11 kW (15 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3565 rpm
Slip 0.97 %
Rated voltage 460 V
Rated current 18.5 A
L. R. Amperes 179 A
LRC 9.7
No load current 9.50 A
Rated torque 21.7 ft.lb
Locked rotor torque 380 %
Breakdown torque 470 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 1.14 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 270 lb
Efficiency
50% 89.0
75% 91.0
100% 91.0
Power factor
50% 0.62
75% 0.75
100% 0.82
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed