WEG E01112ET3YAX160LF3-W W22Xec IE3 11 kW 6P 160L 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E01112ET3YAX160LF3-W

Drop-Ship

Price:
Sale price$4,317.39

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 11 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160L
Output 11 kW (15 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 380/660 V
Rated current 23.1/13.3 A
L. R. Amperes 157/90.4 A
LRC 6.8
No load current 12.5/7.20 A
Rated torque 79.5 ft.lb
Locked rotor torque 250 %
Breakdown torque 270 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 4.58 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 326 lb
Efficiency
50% 89.7
75% 90.3
100% 90.3
Power factor
50% 0.60
75% 0.73
100% 0.80
Electric Motors
Frame 160L
Output 11 kW (15 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 978 rpm
Slip 2.20 %
Rated voltage 400/690 V
Rated current 22.8/13.2 A
L. R. Amperes 162/93.8 A
LRC 7.1
No load current 14.0/8.12 A
Rated torque 79.3 ft.lb
Locked rotor torque 280 %
Breakdown torque 300 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 4.58 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 326 lb
Efficiency
50% 89.0
75% 90.1
100% 90.5
Power factor
50% 0.56
75% 0.70
100% 0.77
Electric Motors
Frame 160L
Output 11 kW (15 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 22.9 A
L. R. Amperes 169 A
LRC 7.4
No load current 15.5 A
Rated torque 79.1 ft.lb
Locked rotor torque 310 %
Breakdown torque 330 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 4.58 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 326 lb
Efficiency
50% 88.3
75% 89.8
100% 90.5
Power factor
50% 0.53
75% 0.67
100% 0.74
Electric Motors
Frame 160L
Output 11 kW (15 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1182 rpm
Slip 1.50 %
Rated voltage 460 V
Rated current 20.1 A
L. R. Amperes 157 A
LRC 7.8
No load current 13.0 A
Rated torque 65.6 ft.lb
Locked rotor torque 350 %
Breakdown torque 370 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 4.58 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 326 lb
Efficiency
50% 88.6
75% 90.4
100% 91.7
Power factor
50% 0.54
75% 0.67
100% 0.75
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed