WEG E00736ET3YAX132SF3-W W22Xec IE3 7.5 kW 2P 132S 3Ph 380-415/660//440-460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00736ET3YAX132SF3-W

Drop-Ship

Price:
Sale price$1,864.94

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-415/660//440-460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 7.5 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 132S
Output 7.5 kW (10 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2915 rpm
Slip 2.83 %
Rated voltage 380/660 V
Rated current 14.4/8.29 A
L. R. Amperes 115/66.3 A
LRC 8.0
No load current 4.75/2.73 A
Rated torque 18.1 ft.lb
Locked rotor torque 240 %
Breakdown torque 300 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 0.5548 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 149 lb
Efficiency
50% 89.2
75% 90.1
100% 90.1
Power factor
50% 0.73
75% 0.83
100% 0.88
Electric Motors
Frame 132S
Output 7.5 kW (10 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2925 rpm
Slip 2.50 %
Rated voltage 400/690 V
Rated current 14.1/8.17 A
L. R. Amperes 120/69.5 A
LRC 8.5
No load current 5.45/3.16 A
Rated torque 18.1 ft.lb
Locked rotor torque 280 %
Breakdown torque 330 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 0.5548 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 149 lb
Efficiency
50% 88.5
75% 89.8
100% 90.3
Power factor
50% 0.68
75% 0.80
100% 0.85
Electric Motors
Frame 132S
Output 7.5 kW (10 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2930 rpm
Slip 2.33 %
Rated voltage 415 V
Rated current 13.9 A
L. R. Amperes 125 A
LRC 9.0
No load current 6.10 A
Rated torque 18.0 ft.lb
Locked rotor torque 300 %
Breakdown torque 350 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 0.5548 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 149 lb
Efficiency
50% 87.9
75% 89.7
100% 90.3
Power factor
50% 0.63
75% 0.76
100% 0.83
Electric Motors
Frame 132S
Output 7.5 kW (10 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3535 rpm
Slip 1.81 %
Rated voltage 460 V
Rated current 12.4 A
L. R. Amperes 117 A
LRC 9.4
No load current 5.00 A
Rated torque 15.0 ft.lb
Locked rotor torque 310 %
Breakdown torque 370 %
Locked rotor time 18s (cold) 10s (hot)
Moment of inertia (J) 0.5548 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 68.0 dB(A)
Approx. weight³ 149 lb
Efficiency
50% 86.9
75% 89.3
100% 90.2
Power factor
50% 0.67
75% 0.78
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM32x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Steel
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap No-Without Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed