WEG E00712ET3YAX160MF3-W W22Xec IE3 7.5 kW 6P 160M 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00712ET3YAX160MF3-W

Drop-Ship

Price:
Sale price$3,277.13

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 7.5 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 160M
Output 7.5 kW (10 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 380/660 V
Rated current 15.6/8.98 A
L. R. Amperes 95.2/54.8 A
LRC 6.1
No load current 7.20/4.15 A
Rated torque 54.5 ft.lb
Locked rotor torque 190 %
Breakdown torque 220 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 3.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 268 lb
Efficiency
50% 88.9
75% 89.0
100% 89.1
Power factor
50% 0.65
75% 0.77
100% 0.82
Electric Motors
Frame 160M
Output 7.5 kW (10 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 400/690 V
Rated current 15.2/8.81 A
L. R. Amperes 95.8/55.5 A
LRC 6.3
No load current 7.80/4.52 A
Rated torque 54.2 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 3.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 268 lb
Efficiency
50% 88.5
75% 89.3
100% 89.1
Power factor
50% 0.62
75% 0.74
100% 0.80
Electric Motors
Frame 160M
Output 7.5 kW (10 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 415 V
Rated current 14.8 A
L. R. Amperes 96.2 A
LRC 6.5
No load current 8.50 A
Rated torque 54.2 ft.lb
Locked rotor torque 240 %
Breakdown torque 280 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 3.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 57.0 dB(A)
Approx. weight³ 268 lb
Efficiency
50% 88.0
75% 89.0
100% 89.1
Power factor
50% 0.58
75% 0.71
100% 0.79
Electric Motors
Frame 160M
Output 7.5 kW (10 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1180 rpm
Slip 1.67 %
Rated voltage 460 V
Rated current 13.3 A
L. R. Amperes 93.1 A
LRC 7.0
No load current 7.40 A
Rated torque 44.8 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 3.33 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 268 lb
Efficiency
50% 87.9
75% 89.5
100% 91.0
Power factor
50% 0.59
75% 0.71
100% 0.78
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM40x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed