WEG E00536ET3YAX132SF3-W W22Xec IE3 5.5 kW 2P 132S 3Ph 380-400-415/660-690//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00536ET3YAX132SF3-W

Drop-Ship

Price:
Sale price$1,641.64

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-400-415/660-690//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 5.5 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 132S
Output 5.5 kW (7.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 380/660 V
Rated current 10.8/6.22 A
L. R. Amperes 85.3/49.1 A
LRC 7.9
No load current 3.70/2.13 A
Rated torque 13.2 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4269 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 136 lb
Efficiency
50% 87.6
75% 88.9
100% 89.2
Power factor
50% 0.71
75% 0.82
100% 0.87
Electric Motors
Frame 132S
Output 5.5 kW (7.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2940 rpm
Slip 2.00 %
Rated voltage 400/690 V
Rated current 10.6/6.14 A
L. R. Amperes 83.7/48.5 A
LRC 7.9
No load current 4.10/2.38 A
Rated torque 13.2 ft.lb
Locked rotor torque 229 %
Breakdown torque 320 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4269 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 136 lb
Efficiency
50% 86.9
75% 88.7
100% 89.4
Power factor
50% 0.66
75% 0.78
100% 0.84
Electric Motors
Frame 132S
Output 5.5 kW (7.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 415 V
Rated current 10.6 A
L. R. Amperes 83.7 A
LRC 7.9
No load current 4.50 A
Rated torque 13.2 ft.lb
Locked rotor torque 250 %
Breakdown torque 350 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 0.4269 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 136 lb
Efficiency
50% 86.1
75% 88.3
100% 89.2
Power factor
50% 0.61
75% 0.74
100% 0.81
Electric Motors
Frame 132S
Output 5.5 kW (7.5 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3550 rpm
Slip 1.39 %
Rated voltage 460 V
Rated current 9.29 A
L. R. Amperes 81.8 A
LRC 8.8
No load current 3.80 A
Rated torque 10.9 ft.lb
Locked rotor torque 270 %
Breakdown torque 380 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 0.4269 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 68.0 dB(A)
Approx. weight³ 136 lb
Efficiency
50% 84.7
75% 87.6
100% 89.5
Power factor
50% 0.65
75% 0.77
100% 0.83
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM32x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Steel
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap No-Without Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed