Description
Standard | IEC 60034-1 |
---|---|
Frequency | 50 Hz |
Voltage | 220-230-240/380-400-415//460 V |
Number of poles | 4 |
Degree of Protection | IP55 |
Synchronous speed | 1500 rpm |
Output rating | 3 kW |
Mounting | B3T |
Flange | Without |
Terminal box¹ | Top |
Enclosure | IC411 - TEFC |
Electric Motors
Frame | 100L |
---|---|
Output | 3 kW (4 HP) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1410 rpm |
Slip | 6.00 % |
Rated voltage | 220/380 V |
Rated current | 11.1/6.42 A |
L. R. Amperes | 72.1/41.7 A |
LRC | 6.5 |
No load current | 4.92/2.85 A |
Rated torque | 15.0 ft.lb |
Locked rotor torque | 280 % |
Breakdown torque | 260 % |
Locked rotor time | 25s (cold) 14s (hot) |
Moment of inertia (J) | 0.2307 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 53.0 dB(A) |
Approx. weight³ | 75.6 lb |
Efficiency
50% | 85.4 |
---|---|
75% | 85.5 |
100% | 85.5 |
Power factor
50% | 0.65 |
---|---|
75% | 0.77 |
100% | 0.83 |
Electric Motors
Frame | 100L |
---|---|
Output | 3 kW (4 HP) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1420 rpm |
Slip | 5.33 % |
Rated voltage | 230/400 V |
Rated current | 10.9/6.25 A |
L. R. Amperes | 76.1/43.7 A |
LRC | 7.0 |
No load current | 5.57/3.20 A |
Rated torque | 14.9 ft.lb |
Locked rotor torque | 320 % |
Breakdown torque | 300 % |
Locked rotor time | 25s (cold) 14s (hot) |
Moment of inertia (J) | 0.2307 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 53.0 dB(A) |
Approx. weight³ | 75.6 lb |
Efficiency
50% | 85.0 |
---|---|
75% | 85.6 |
100% | 85.6 |
Power factor
50% | 0.60 |
---|---|
75% | 0.73 |
100% | 0.81 |
Electric Motors
Frame | 100L |
---|---|
Output | 3 kW (4 HP) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1430 rpm |
Slip | 4.67 % |
Rated voltage | 240/415 V |
Rated current | 10.8/6.22 A |
L. R. Amperes | 80.7/46.6 A |
LRC | 7.5 |
No load current | 6.05/3.50 A |
Rated torque | 14.8 ft.lb |
Locked rotor torque | 360 % |
Breakdown torque | 330 % |
Locked rotor time | 25s (cold) 14s (hot) |
Moment of inertia (J) | 0.2307 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 53.0 dB(A) |
Approx. weight³ | 75.6 lb |
Efficiency
50% | 84.3 |
---|---|
75% | 85.5 |
100% | 86.0 |
Power factor
50% | 0.56 |
---|---|
75% | 0.70 |
100% | 0.78 |
Electric Motors
Frame | 100L |
---|---|
Output | 3 kW (4 HP) |
Number of Poles | 4 |
Frequency | 60 Hz |
Rated speed | 1735 rpm |
Slip | 3.61 % |
Rated voltage | 460 V |
Rated current | 5.52 A |
L. R. Amperes | 44.2 A |
LRC | 8.0 |
No load current | 2.95 A |
Rated torque | 12.2 ft.lb |
Locked rotor torque | 380 % |
Breakdown torque | 390 % |
Locked rotor time | 25s (cold) 14s (hot) |
Moment of inertia (J) | 0.2307 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 54.0 dB(A) |
Approx. weight³ | 75.6 lb |
Efficiency
50% | 84.0 |
---|---|
75% | 86.5 |
100% | 87.5 |
Power factor
50% | 0.56 |
---|---|
75% | 0.69 |
100% | 0.78 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Dip and Bake Polyester |
Main terminal box hole | 2xM25x1,5 |
Terminal Block | BMC - 6 pins |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | RAL 5009 205P (ISO 12944 - C3) |
Grounding Lugs | Double |
Fan Cover material | Steel |
Tropicalized Painting | Without |
Fan material | Conductive Plastic |
Bearing cap | No-Without Bearing Cap |
Winding thermal protection | Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C |
Balancing Method | 1/2 Key |
Drip Cover | Without |
Overload protector (phenolic) | Without overload protector |
Connection Cables Quantity | 6 |