WEG E00312ET3YAX132SF3-W W22Xec IE3 3 kW 6P 132S 3Ph 380-415/660//440-460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00312ET3YAX132SF3-W

Drop-Ship

Price:
Sale price$1,713.25

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 380-415/660//440-460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1000 rpm
Output rating 3 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 132S
Output 3 kW (4 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 965 rpm
Slip 3.50 %
Rated voltage 380/660 V
Rated current 7.01/4.04 A
L. R. Amperes 39.3/22.6 A
LRC 5.6
No load current 3.64/2.10 A
Rated torque 21.9 ft.lb
Locked rotor torque 160 %
Breakdown torque 210 %
Locked rotor time 72s (cold) 40s (hot)
Moment of inertia (J) 0.9879 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 143 lb
Efficiency
50% 85.0
75% 85.6
100% 85.6
Power factor
50% 0.57
75% 0.69
100% 0.76
Electric Motors
Frame 132S
Output 3 kW (4 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 400/690 V
Rated current 6.93/4.02 A
L. R. Amperes 42.3/24.5 A
LRC 6.1
No load current 4.00/2.32 A
Rated torque 21.8 ft.lb
Locked rotor torque 190 %
Breakdown torque 240 %
Locked rotor time 72s (cold) 40s (hot)
Moment of inertia (J) 0.9879 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 143 lb
Efficiency
50% 85.0
75% 85.6
100% 85.6
Power factor
50% 0.53
75% 0.66
100% 0.73
Electric Motors
Frame 132S
Output 3 kW (4 HP)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 415 V
Rated current 6.87 A
L. R. Amperes 45.3 A
LRC 6.6
No load current 4.28 A
Rated torque 21.7 ft.lb
Locked rotor torque 220 %
Breakdown torque 260 %
Locked rotor time 72s (cold) 40s (hot)
Moment of inertia (J) 0.9879 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 143 lb
Efficiency
50% 85.2
75% 85.8
100% 85.6
Power factor
50% 0.49
75% 0.63
100% 0.71
Electric Motors
Frame 132S
Output 3 kW (4 HP)
Number of Poles 6
Frequency 60 Hz
Rated speed 1175 rpm
Slip 2.08 %
Rated voltage 460 V
Rated current 6.15 A
L. R. Amperes 46.1 A
LRC 7.5
No load current 3.80 A
Rated torque 18.0 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 72s (cold) 40s (hot)
Moment of inertia (J) 0.9879 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 55.0 dB(A)
Approx. weight³ 143 lb
Efficiency
50% 85.0
75% 86.5
100% 87.5
Power factor
50% 0.48
75% 0.61
100% 0.70
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM32x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Steel
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap No-Without Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed