The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.
Standard |
IEC 60034-1 |
Frequency |
50 Hz |
Voltage |
380-400-415/660-690 V |
Number of poles |
6 |
Degree of Protection |
IP55 |
Synchronous speed |
1000 rpm |
Output rating |
2.2 kW |
Mounting |
B3T |
Flange |
Without |
Terminal box¹ |
Top |
Enclosure |
IC411 - TEFC |
Electric Motors
Frame |
112M |
Output |
2.2 kW (3 HP) |
Number of Poles |
6 |
Frequency |
50 Hz |
Rated speed |
960 rpm |
Slip |
4.00 % |
Rated voltage |
380-400-415/660-690 V |
Rated current |
5.57-5.29-5.10/3.21-3.07 A |
L. R. Amperes |
36.2-34.4-33.1/20.8-19.9 A |
LRC |
6.5 |
No load current |
3.16-3.00-2.89/1.82-1.74 A |
Rated torque |
16.2 ft.lb |
Locked rotor torque |
270 % |
Breakdown torque |
270 % |
Locked rotor time |
46s (cold) 26s (hot) |
Moment of inertia (J) |
0.6091 sq.ft.lb |
Design |
N |
Insulation Class |
F |
Temperature rise |
80 K |
Duty Cycle |
S1 |
Starting Method |
Direct On Line |
Ambient temperature |
-20°C to +40°C |
Altitude |
1000 m.a.s.l. |
Degree of Protection |
IP55 |
Enclosure |
IC411 - TEFC |
Mounting |
B3T |
Rotation¹ |
Both (CW and CCW) |
Noise level² |
49.0 dB(A) |
Approx. weight³ |
101 lb |
Efficiency
50% |
83.0 |
75% |
84.5 |
100% |
84.5 |
Power factor
50% |
0.48 |
75% |
0.61 |
100% |
0.71 |
Features
Frame Material |
Cast Iron |
Impregnation Method |
Dip and Bake Polyester |
Main terminal box hole |
2xM32x1,5 |
Terminal Block |
BMC - 6 pins |
Shaft Locking Device |
Without |
Drain |
Rubber, automatic |
Shaft Material |
SAE 1040/45 Carbon Steel |
Painting |
RAL 5009 205P (ISO 12944 - C3) |
Grounding Lugs |
Double |
Fan Cover material |
Steel |
Tropicalized Painting |
Without |
Fan material |
Conductive Plastic |
Bearing cap |
No-Without Bearing Cap |
Winding thermal protection |
Thermistor - 2 wires 1 per phase 140°C
Thermistor - 2 wires 1 per phase 155°C |
Drip Cover |
Without |
Overload protector (phenolic) |
Without overload protector |
Connection Cables Quantity |
6 |
Features
Frame Material |
Cast Iron |
Impregnation Method |
Dip and Bake Polyester |
Main terminal box hole |
2xM32x1,5 |
Terminal Block |
BMC - 6 pins |
Shaft Locking Device |
Without |
Drain |
Rubber, automatic |
Shaft Material |
SAE 1040/45 Carbon Steel |
Painting |
RAL 5009 205P (ISO 12944 - C3) |
Grounding Lugs |
Double |
Fan Cover material |
Steel |
Tropicalized Painting |
Without |
Fan material |
Conductive Plastic |
Bearing cap |
No-Without Bearing Cap |
Winding thermal protection |
Thermistor - 2 wires 1 per phase 140°C
Thermistor - 2 wires 1 per phase 155°C |
Drip Cover |
Without |
Overload protector (phenolic) |
Without overload protector |
Connection Cables Quantity |
6 |