Description
The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.
| Standard | IEC 60034-1 |
|---|---|
| Frequency | 50 Hz |
| Voltage | 220-230-240/380-400-415 V |
| Number of poles | 6 |
| Degree of Protection | IP55 |
| Synchronous speed | 1000 rpm |
| Output rating | 1.5 kW |
| Mounting | B3T |
| Flange | Without |
| Terminal box¹ | Top |
| Enclosure | IC411 - TEFC |
Electric Motors
| Frame | 100L |
|---|---|
| Output | 1.5 kW (2 HP) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 950 rpm |
| Slip | 5.00 % |
| Rated voltage | 220/380 V |
| Rated current | 6.44/3.73 A |
| L. R. Amperes | 33.5/19.4 A |
| LRC | 5.2 |
| No load current | 3.63/2.10 A |
| Rated torque | 11.1 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 229 % |
| Locked rotor time | 55s (cold) 31s (hot) |
| Moment of inertia (J) | 0.3384 sq.ft.lb |
| Design | N |
| Insulation Class | F |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3T |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 44.0 dB(A) |
| Approx. weight³ | 74.2 lb |
Efficiency
| 50% | 82.3 |
|---|---|
| 75% | 82.6 |
| 100% | 82.5 |
Power factor
| 50% | 0.53 |
|---|---|
| 75% | 0.66 |
| 100% | 0.74 |
Electric Motors
| Frame | 100L |
|---|---|
| Output | 1.5 kW (2 HP) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 955 rpm |
| Slip | 4.50 % |
| Rated voltage | 230/400 V |
| Rated current | 6.43/3.70 A |
| L. R. Amperes | 35.4/20.4 A |
| LRC | 5.5 |
| No load current | 3.83/2.20 A |
| Rated torque | 11.1 ft.lb |
| Locked rotor torque | 270 % |
| Breakdown torque | 270 % |
| Locked rotor time | 55s (cold) 31s (hot) |
| Moment of inertia (J) | 0.3384 sq.ft.lb |
| Design | N |
| Insulation Class | F |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3T |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 44.0 dB(A) |
| Approx. weight³ | 74.2 lb |
Efficiency
| 50% | 81.5 |
|---|---|
| 75% | 82.5 |
| 100% | 82.5 |
Power factor
| 50% | 0.49 |
|---|---|
| 75% | 0.62 |
| 100% | 0.71 |
Electric Motors
| Frame | 100L |
|---|---|
| Output | 1.5 kW (2 HP) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 960 rpm |
| Slip | 4.00 % |
| Rated voltage | 240/415 V |
| Rated current | 6.42/3.71 A |
| L. R. Amperes | 37.2/21.5 A |
| LRC | 5.8 |
| No load current | 4.15/2.40 A |
| Rated torque | 11.0 ft.lb |
| Locked rotor torque | 300 % |
| Breakdown torque | 300 % |
| Locked rotor time | 55s (cold) 31s (hot) |
| Moment of inertia (J) | 0.3384 sq.ft.lb |
| Design | N |
| Insulation Class | F |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3T |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 44.0 dB(A) |
| Approx. weight³ | 74.2 lb |
Efficiency
| 50% | 80.6 |
|---|---|
| 75% | 82.3 |
| 100% | 82.8 |
Power factor
| 50% | 0.46 |
|---|---|
| 75% | 0.59 |
| 100% | 0.68 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Main terminal box hole | 2xM25x1,5 |
| Terminal Block | BMC - 6 pins |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 5009 205P (ISO 12944 - C3) |
| Grounding Lugs | Double |
| Fan Cover material | Steel |
| Tropicalized Painting | Without |
| Fan material | Conductive Plastic |
| Bearing cap | No-Without Bearing Cap |
| Winding thermal protection | Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 6 |