WEG E00136ET3WAX80F3-W22 W22Xec IE3 1.1 kW 2P 80 3Ph 220-230-240/380-400-415//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00136ET3WAX80F3-W22

Drop-Ship

Price:
Sale price$547.48

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 220-230-240/380-400-415//460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3000 rpm
Output rating 1.1 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 80
Output 1.1 kW (1.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2815 rpm
Slip 6.17 %
Rated voltage 220/380 V
Rated current 4.15/2.40 A
L. R. Amperes 27.8/16.1 A
LRC 6.7
No load current 2.07/1.20 A
Rated torque 2.75 ft.lb
Locked rotor torque 360 %
Breakdown torque 320 %
Locked rotor time 41s (cold) 23s (hot)
Moment of inertia (J) 0.0221 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 32.3 lb
Efficiency
50% 82.0
75% 83.0
100% 83.0
Power factor
50% 0.66
75% 0.78
100% 0.84
Electric Motors
Frame 80
Output 1.1 kW (1.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2835 rpm
Slip 5.50 %
Rated voltage 230/400 V
Rated current 4.16/2.39 A
L. R. Amperes 29.9/17.2 A
LRC 7.2
No load current 2.43/1.40 A
Rated torque 2.73 ft.lb
Locked rotor torque 409 %
Breakdown torque 360 %
Locked rotor time 41s (cold) 23s (hot)
Moment of inertia (J) 0.0221 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 32.3 lb
Efficiency
50% 81.5
75% 83.0
100% 83.0
Power factor
50% 0.60
75% 0.73
100% 0.80
Electric Motors
Frame 80
Output 1.1 kW (1.5 HP)
Number of Poles 2
Frequency 50 Hz
Rated speed 2850 rpm
Slip 5.00 %
Rated voltage 240/415 V
Rated current 4.17/2.41 A
L. R. Amperes 32.1/18.6 A
LRC 7.7
No load current 2.77/1.60 A
Rated torque 2.72 ft.lb
Locked rotor torque 450 %
Breakdown torque 390 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.0221 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 32.3 lb
Efficiency
50% 80.0
75% 83.0
100% 83.4
Power factor
50% 0.54
75% 0.67
100% 0.76
Electric Motors
Frame 80
Output 1.1 kW (1.5 HP)
Number of Poles 2
Frequency 60 Hz
Rated speed 3460 rpm
Slip 3.89 %
Rated voltage 460 V
Rated current 2.08 A
L. R. Amperes 17.7 A
LRC 8.5
No load current 1.20 A
Rated torque 2.24 ft.lb
Locked rotor torque 490 %
Breakdown torque 450 %
Locked rotor time 39s (cold) 22s (hot)
Moment of inertia (J) 0.0221 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 32.3 lb
Efficiency
50% 78.5
75% 81.5
100% 84.0
Power factor
50% 0.59
75% 0.71
100% 0.79
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM20x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Steel
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap No-Without Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method Not Balanced
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6