WEG E00118ET3WAX90SF3-W2 W22Xec IE3 1.1 kW 4P 90S 3Ph 220-230-240/380-400-415//460 V 50 Hz IC411 - TEFC - B3T

WEGSKU: E00118ET3WAX90SF3-W2

Drop-Ship

Price:
Sale price$587.51

Description

The W22Xec motor offer safety and reliability for operation in a great variety of applications that require a non-incendive motor (Zone 2). It provides safety and complies with efficiency level specified by IEC 60034-30-1. It meets the requirements of installations where the flammable mixture is not often present, but may present risks.

Standard IEC 60034-1
Frequency 50 Hz
Voltage 220-230-240/380-400-415//460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1500 rpm
Output rating 1.1 kW
Mounting B3T
Flange Without
Terminal box¹ Top
Enclosure IC411 - TEFC


Electric Motors
Frame 90S
Output 1.1 kW (1.5 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1435 rpm
Slip 4.33 %
Rated voltage 220/380 V
Rated current 4.18/2.42 A
L. R. Amperes 26.3/15.2 A
LRC 6.3
No load current 2.07/1.20 A
Rated torque 5.40 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 0.1296 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 44.9 lb
Efficiency
50% 84.0
75% 84.1
100% 84.1
Power factor
50% 0.64
75% 0.76
100% 0.82
Electric Motors
Frame 90S
Output 1.1 kW (1.5 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1445 rpm
Slip 3.67 %
Rated voltage 230/400 V
Rated current 4.16/2.39 A
L. R. Amperes 27.4/15.8 A
LRC 6.6
No load current 2.43/1.40 A
Rated torque 5.37 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 0.1296 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 44.9 lb
Efficiency
50% 83.0
75% 84.1
100% 84.1
Power factor
50% 0.59
75% 0.72
100% 0.79
Electric Motors
Frame 90S
Output 1.1 kW (1.5 HP)
Number of Poles 4
Frequency 50 Hz
Rated speed 1450 rpm
Slip 3.33 %
Rated voltage 240/415 V
Rated current 4.08/2.36 A
L. R. Amperes 29.0/16.8 A
LRC 7.1
No load current 2.59/1.50 A
Rated torque 5.35 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.1296 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 49.0 dB(A)
Approx. weight³ 44.9 lb
Efficiency
50% 82.0
75% 84.1
100% 84.1
Power factor
50% 0.55
75% 0.69
100% 0.77
Electric Motors
Frame 90S
Output 1.1 kW (1.5 HP)
Number of Poles 4
Frequency 60 Hz
Rated speed 1755 rpm
Slip 2.50 %
Rated voltage 460 V
Rated current 2.07 A
L. R. Amperes 16.4 A
LRC 7.9
No load current 1.30 A
Rated torque 4.42 ft.lb
Locked rotor torque 270 %
Breakdown torque 340 %
Locked rotor time 28s (cold) 16s (hot)
Moment of inertia (J) 0.1296 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3T
Rotation¹ Both (CW and CCW)
Noise level² 51.0 dB(A)
Approx. weight³ 44.9 lb
Efficiency
50% 80.0
75% 84.0
100% 86.5
Power factor
50% 0.57
75% 0.70
100% 0.77
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole 2xM25x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 205P (ISO 12944 - C3)
Grounding Lugs Double
Fan Cover material Steel
Tropicalized Painting Without
Fan material Conductive Plastic
Bearing cap No-Without Bearing Cap
Winding thermal protection Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed