Description
Standard | IEC 60034-1 |
---|---|
Frequency | 50 Hz |
Voltage | 220-230-240/380-400-415//460 V |
Number of poles | 2 |
Degree of Protection | IP55 |
Synchronous speed | 3000 rpm |
Output rating | 0.18 kW |
Mounting | B3T |
Flange | Without |
Terminal box¹ | Top |
Enclosure | IC411 - TEFC |
Electric Motors
Frame | 63 |
---|---|
Output | 0.18 kW (0.25 HP) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2810 rpm |
Slip | 6.33 % |
Rated voltage | 220/380 V |
Rated current | 0.890/0.515 A |
L. R. Amperes | 4.36/2.52 A |
LRC | 4.9 |
No load current | 0.570/0.330 A |
Rated torque | 0.451 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 240 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 0.0033 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 52.0 dB(A) |
Approx. weight³ | 20.2 lb |
Efficiency
50% | 58.0 |
---|---|
75% | 63.0 |
100% | 64.0 |
Power factor
50% | 0.61 |
---|---|
75% | 0.75 |
100% | 0.83 |
Electric Motors
Frame | 63 |
---|---|
Output | 0.18 kW (0.25 HP) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2830 rpm |
Slip | 5.67 % |
Rated voltage | 230/400 V |
Rated current | 0.894/0.514 A |
L. R. Amperes | 4.56/2.62 A |
LRC | 5.1 |
No load current | 0.609/0.350 A |
Rated torque | 0.448 ft.lb |
Locked rotor torque | 250 % |
Breakdown torque | 270 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 0.0033 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 52.0 dB(A) |
Approx. weight³ | 20.2 lb |
Efficiency
50% | 57.0 |
---|---|
75% | 62.0 |
100% | 64.0 |
Power factor
50% | 0.57 |
---|---|
75% | 0.70 |
100% | 0.79 |
Electric Motors
Frame | 63 |
---|---|
Output | 0.18 kW (0.25 HP) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2845 rpm |
Slip | 5.17 % |
Rated voltage | 240/415 V |
Rated current | 0.896/0.518 A |
L. R. Amperes | 4.75/2.75 A |
LRC | 5.3 |
No load current | 0.657/0.380 A |
Rated torque | 0.446 ft.lb |
Locked rotor torque | 270 % |
Breakdown torque | 300 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 0.0033 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 52.0 dB(A) |
Approx. weight³ | 20.2 lb |
Efficiency
50% | 55.0 |
---|---|
75% | 60.9 |
100% | 63.6 |
Power factor
50% | 0.53 |
---|---|
75% | 0.66 |
100% | 0.76 |
Electric Motors
Frame | 63 |
---|---|
Output | 0.18 kW (0.25 HP) |
Number of Poles | 2 |
Frequency | 60 Hz |
Rated speed | 3455 rpm |
Slip | 4.03 % |
Rated voltage | 460 V |
Rated current | 0.470 A |
L. R. Amperes | 2.68 A |
LRC | 5.7 |
No load current | 0.340 A |
Rated torque | 0.367 ft.lb |
Locked rotor torque | 320 % |
Breakdown torque | 360 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 0.0033 sq.ft.lb |
Design | N |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3T |
Rotation¹ | Both (CW and CCW) |
Noise level² | 56.0 dB(A) |
Approx. weight³ | 20.2 lb |
Efficiency
50% | 55.9 |
---|---|
75% | 59.4 |
100% | 65.0 |
Power factor
50% | 0.55 |
---|---|
75% | 0.65 |
100% | 0.74 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Dip and Bake Polyester |
Main terminal box hole | 2xM20x1,5 |
Terminal Block | BMC - 6 pins |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | RAL 5009 205P (ISO 12944 - C3) |
Grounding Lugs | Double |
Fan Cover material | Steel |
Tropicalized Painting | Without |
Fan material | Conductive Plastic |
Bearing cap | No-Without Bearing Cap |
Winding thermal protection | Thermistor - 2 wires 1 per phase 140°C Thermistor - 2 wires 1 per phase 155°C |
Balancing Method | Not Balanced |
Drip Cover | Without |
Overload protector (phenolic) | Without overload protector |
Connection Cables Quantity | 6 |