Description
WEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I/Zone 1. Motors are certified for VFD service.
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60 Hz |
| Voltage | 460 V |
| Number of poles | 6 |
| Degree of Protection | IP55 |
| Synchronous speed | 1200 rpm |
| Output rating | 350 HP |
| Mounting | F-1 |
| Flange | Without |
| Terminal box¹ | Left position |
| Enclosure | IC411 - TEFC |
Electric Motors
| Frame | 586/7T |
|---|---|
| Output | 350 HP (260 kW) |
| Number of Poles | 6 |
| Frequency | 60 Hz |
| Rated speed | 1192 rpm |
| Slip | 0.67 % |
| Rated voltage | 460 V |
| Rated current | 421 A |
| L. R. Amperes | 2526 A |
| LRC | 6.0x(Code G) |
| No load current | 170 A |
| Rated torque | 1540 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 210 % |
| Locked rotor time | 52s (cold) 29s (hot) |
| Moment of inertia (J) | 328 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 77.0 dB(A) |
| Approx. weight³ | 4376 lb |
Efficiency
| 50% | 95.4 |
|---|---|
| 75% | 95.8 |
| 100% | 95.8 |
Power factor
| 50% | 0.67 |
|---|---|
| 75% | 0.77 |
| 100% | 0.81 |
Electric Motors
| Frame | 586/7T |
|---|---|
| Output | 300 HP (220 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 992 rpm |
| Slip | 0.80 % |
| Rated voltage | 380 V |
| Rated current | 433 A |
| L. R. Amperes | 2425 A |
| LRC | 5.6x(Code F) |
| No load current | 165 A |
| Rated torque | 1590 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 200 % |
| Locked rotor time | 45s (cold) 25s (hot) |
| Moment of inertia (J) | 328 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 73.0 dB(A) |
| Approx. weight³ | 4376 lb |
Efficiency
| 50% | 95.4 |
|---|---|
| 75% | 95.8 |
| 100% | 95.4 |
Power factor
| 50% | 0.68 |
|---|---|
| 75% | 0.78 |
| 100% | 0.81 |
Electric Motors
| Frame | 586/7T |
|---|---|
| Output | 300 HP (220 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 993 rpm |
| Slip | 0.70 % |
| Rated voltage | 400 V |
| Rated current | 414 A |
| L. R. Amperes | 2567 A |
| LRC | 6.2x(Code G) |
| No load current | 175 A |
| Rated torque | 1590 ft.lb |
| Locked rotor torque | 210 % |
| Breakdown torque | 220 % |
| Locked rotor time | 45s (cold) 25s (hot) |
| Moment of inertia (J) | 328 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 73.0 dB(A) |
| Approx. weight³ | 4376 lb |
Efficiency
| 50% | 95.4 |
|---|---|
| 75% | 95.8 |
| 100% | 95.8 |
Power factor
| 50% | 0.64 |
|---|---|
| 75% | 0.75 |
| 100% | 0.80 |
Electric Motors
| Frame | 586/7T |
|---|---|
| Output | 300 HP (220 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 994 rpm |
| Slip | 0.60 % |
| Rated voltage | 415 V |
| Rated current | 410 A |
| L. R. Amperes | 2706 A |
| LRC | 6.6x(Code H) |
| No load current | 185 A |
| Rated torque | 1580 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 240 % |
| Locked rotor time | 45s (cold) 25s (hot) |
| Moment of inertia (J) | 328 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 73.0 dB(A) |
| Approx. weight³ | 4376 lb |
Efficiency
| 50% | 95.0 |
|---|---|
| 75% | 95.4 |
| 100% | 95.8 |
Power factor
| 50% | 0.61 |
|---|---|
| 75% | 0.73 |
| 100% | 0.78 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | 2xNPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Sinterized, Exd |
| Shaft Material | SAE 4140 Carbon Steel |
| Painting | RAL 5009 202P (ISO 12944 - C4) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Aluminum |
| Bearing cap | Yes- Bearing Cap |
| Bolt Material | Carbon Steel |
| Winding thermal protection | Thermostat - 2 wires 1 per phase 155°C |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 12 |