WEG 22036ET3Y315L-W22 W22 Tru-Metric IE3 300 HP 2P 315L 3Ph 460//380-415 V 60 Hz IC411 - TEFC - B3L(E)

WEGSKU: 22036ET3Y315L-W22

GTIN :

MPN :

Dropship

Price:
Sale price$44,212.00

Description

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460//380-415 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 300 HP
Mounting B3L(E)
Flange Without
Terminal box¹ Right position
Enclosure IC411 - TEFC


Electric Motors
Frame 315L
Output 300 HP (220 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3580 rpm
Slip 0.56 %
Rated voltage 460 V
Rated current 315 A
L. R. Amperes 2489 A
LRC 7.9
No load current 82.5 A
Rated torque 440 ft.lb
Locked rotor torque 270 %
Breakdown torque 320 %
Locked rotor time 79s (cold) 44s (hot)
Moment of inertia (J) 88.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 82.0 dB(A)
Approx. weight³ 3021 lb
Efficiency
50% 95.4
75% 95.8
100% 96.2
Power factor
50% 0.84
75% 0.89
100% 0.91
Electric Motors
Frame 315L
Output 300 HP (220 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2975 rpm
Slip 0.83 %
Rated voltage 380 V
Rated current 381 A
L. R. Amperes 2934 A
LRC 7.7
No load current 84.6 A
Rated torque 530 ft.lb
Locked rotor torque 210 %
Breakdown torque 229 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 88.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 78.0 dB(A)
Approx. weight³ 3021 lb
Efficiency
50% 93.1
75% 96.4
100% 96.5
Power factor
50% 0.86
75% 0.90
100% 0.91
Electric Motors
Frame 315L
Output 300 HP (220 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2980 rpm
Slip 0.67 %
Rated voltage 400 V
Rated current 361 A
L. R. Amperes 2780 A
LRC 7.7
No load current 90.0 A
Rated torque 529 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 88.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 78.0 dB(A)
Approx. weight³ 3021 lb
Efficiency
50% 96.1
75% 96.5
100% 96.7
Power factor
50% 0.84
75% 0.89
100% 0.91
Electric Motors
Frame 315L
Output 300 HP (220 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2980 rpm
Slip 0.67 %
Rated voltage 415 V
Rated current 347 A
L. R. Amperes 2672 A
LRC 7.7
No load current 94.2 A
Rated torque 529 ft.lb
Locked rotor torque 260 %
Breakdown torque 280 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 88.3 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 78.0 dB(A)
Approx. weight³ 3021 lb
Efficiency
50% 96.1
75% 96.5
100% 96.8
Power factor
50% 0.83
75% 0.88
100% 0.91
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM63x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed