WEG 20012ET3G505-W22 W22 NEMA Premium Efficiency 200 HP 6P 504/5T 3Ph 460 V 60 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 20012ET3G505-W22

GTIN :

MPN :

Dropship

Price:
Sale price$25,133.00

Description

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1200 rpm
Output rating 200 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1190 rpm
Slip 0.83 %
Rated voltage 460 V
Rated current 237 A
L. R. Amperes 1469 A
LRC 6.2x(Code G)
No load current 85.0 A
Rated torque 883 ft.lb
Locked rotor torque 220 %
Breakdown torque 229 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 95.0
75% 95.4
100% 95.8
Power factor
50% 0.70
75% 0.80
100% 0.83
Electric Motors
Frame 504/5T
Output 175 HP (132 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 380 V
Rated current 247 A
L. R. Amperes 1359 A
LRC 5.5x(Code F)
No load current 81.0 A
Rated torque 933 ft.lb
Locked rotor torque 190 %
Breakdown torque 210 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 94.8
75% 95.1
100% 95.4
Power factor
50% 0.71
75% 0.82
100% 0.85
Electric Motors
Frame 504/5T
Output 175 HP (132 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 241 A
L. R. Amperes 1494 A
LRC 6.2x(Code G)
No load current 86.0 A
Rated torque 928 ft.lb
Locked rotor torque 220 %
Breakdown torque 240 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 94.5
75% 95.1
100% 95.4
Power factor
50% 0.67
75% 0.79
100% 0.83
Electric Motors
Frame 504/5T
Output 175 HP (132 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 235 A
L. R. Amperes 1598 A
LRC 6.8x(Code H)
No load current 91.0 A
Rated torque 928 ft.lb
Locked rotor torque 240 %
Breakdown torque 250 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 94.4
75% 95.1
100% 95.4
Power factor
50% 0.65
75% 0.78
100% 0.82
Electric Motors
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 380 V
Rated current 284 A
L. R. Amperes 1363 A
LRC 4.8x(Code D)
No load current 81.0 A
Rated torque 1070 ft.lb
Locked rotor torque 170 %
Breakdown torque 180 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 95.0
75% 95.0
100% 94.5
Power factor
50% 0.76
75% 0.83
100% 0.85
Electric Motors
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 271 A
L. R. Amperes 1491 A
LRC 5.5x(Code F)
No load current 86.0 A
Rated torque 1060 ft.lb
Locked rotor torque 190 %
Breakdown torque 210 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 95.0
75% 95.0
100% 95.0
Power factor
50% 0.72
75% 0.81
100% 0.84
Electric Motors
Frame 504/5T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 265 A
L. R. Amperes 1590 A
LRC 6.0x(Code G)
No load current 91.0 A
Rated torque 1060 ft.lb
Locked rotor torque 210 %
Breakdown torque 220 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 2459 lb
Efficiency
50% 95.0
75% 95.0
100% 95.0
Power factor
50% 0.70
75% 0.80
100% 0.83
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xNPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 12
Downloads

You may also like

Recently viewed