WEG 15036ST3QIE445TS-W22 W22 IEEE 841 NEMA Premium Efficiency 150 HP 2P 444/5TS 3Ph 460 V 60 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 15036ST3QIE445TS-W22

GTIN : 7891327134744

MPN :

Dropship

Price:
Sale price$21,433.00

Description

The W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 150 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 444/5TS
Output 150 HP (110 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3570 rpm
Slip 0.83 %
Rated voltage 460 V
Rated current 163 A
L. R. Amperes 1060 A
LRC 6.5x(Code G)
No load current 41.0 A
Rated torque 221 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 39s (cold) 22s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.1
75% 95.0
100% 95.0
Power factor
50% 0.83
75% 0.88
100% 0.89
Electric Motors
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 380 V
Rated current 162 A
L. R. Amperes 988 A
LRC 6.1x(Code F)
No load current 41.0 A
Rated torque 221 ft.lb
Locked rotor torque 170 %
Breakdown torque 229 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 93.7
75% 94.4
100% 95.0
Power factor
50% 0.81
75% 0.88
100% 0.89
Electric Motors
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 154 A
L. R. Amperes 1063 A
LRC 6.9x(Code G)
No load current 43.1 A
Rated torque 221 ft.lb
Locked rotor torque 190 %
Breakdown torque 250 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.1
75% 94.9
100% 95.0
Power factor
50% 0.79
75% 0.88
100% 0.89
Electric Motors
Frame 444/5TS
Output 125 HP
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 148 A
L. R. Amperes 1080 A
LRC 7.3x(Code G)
No load current 45.1 A
Rated torque 221 ft.lb
Locked rotor torque 200 %
Breakdown torque 280 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.1
75% 94.9
100% 95.0
Power factor
50% 0.77
75% 0.87
100% 0.89
Electric Motors
Frame 444/5TS
Output 150 HP (110 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 200 A
L. R. Amperes 1020 A
LRC 5.1x(Code D)
No load current 41.0 A
Rated torque 266 ft.lb
Locked rotor torque 140 %
Breakdown torque 190 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.1
75% 94.5
100% 94.1
Power factor
50% 0.86
75% 0.89
100% 0.89
Electric Motors
Frame 444/5TS
Output 150 HP (110 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 400 V
Rated current 189 A
L. R. Amperes 1077 A
LRC 5.7x(Code E)
No load current 43.1 A
Rated torque 266 ft.lb
Locked rotor torque 160 %
Breakdown torque 210 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.5
75% 95.0
100% 94.5
Power factor
50% 0.84
75% 0.89
100% 0.89
Electric Motors
Frame 444/5TS
Output 150 HP (110 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 415 V
Rated current 182 A
L. R. Amperes 1110 A
LRC 6.1x(Code F)
No load current 45.1 A
Rated torque 266 ft.lb
Locked rotor torque 170 %
Breakdown torque 229 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 39.1 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 77.0 dB(A)
Approx. weight³ 1744 lb
Efficiency
50% 94.5
75% 95.0
100% 94.5
Power factor
50% 0.83
75% 0.88
100% 0.89
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System Extended in Stainless Steel, at Drive end and Non-drive end
Main terminal box hole 2xNPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Type T, Threaded
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting According to IEEE-841 (96h)
Joints Seal Molykote
Foot flatness (0.005 pol) 0.127 mm
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 3
Downloads

You may also like

Recently viewed