WEG 10018EG3E405T-W22 W22 Super Premium Efficiency 100 HP 4P 404/5T 3Ph 208-230/460 V 60 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 10018EG3E405T-W22

GTIN : 7891327744493

MPN :

Dropship

Price:
Sale price$12,858.00

Description

With cast iron frame, flexible mounting, solid feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications. Carry CSA Certified for Division 2 on the Nameplate as standard.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 208-230/460 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1800 rpm
Output rating 100 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1785 rpm
Slip 0.83 %
Rated voltage 230/460 V
Rated current 232/116 A
L. R. Amperes 2297/1148 A
LRC 9.9x(Code L)
No load current 94.0/47.0 A
Rated torque 294 ft.lb
Locked rotor torque 330 %
Breakdown torque 350 %
Locked rotor time 30s (cold) 17s (hot)
Moment of inertia (J) 28.7 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 68.0 dB(A)
Approx. weight³ 1236 lb
Efficiency
50% 95.0
75% 95.8
100% 96.2
Power factor
50% 0.70
75% 0.80
100% 0.84
Electric Motors
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 139 A
L. R. Amperes 1084 A
LRC 7.8x(Code J)
No load current 46.0 A
Rated torque 355 ft.lb
Locked rotor torque 250 %
Breakdown torque 270 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 28.7 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1236 lb
Efficiency
50% 94.6
75% 95.0
100% 95.0
Power factor
50% 0.75
75% 0.83
100% 0.86
Electric Motors
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 134 A
L. R. Amperes 1126 A
LRC 8.4x(Code J)
No load current 50.0 A
Rated torque 355 ft.lb
Locked rotor torque 280 %
Breakdown torque 300 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 28.7 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1236 lb
Efficiency
50% 94.6
75% 95.0
100% 95.0
Power factor
50% 0.72
75% 0.81
100% 0.85
Electric Motors
Frame 404/5T
Output 100 HP (75 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 130 A
L. R. Amperes 1170 A
LRC 9.0x(Code K)
No load current 53.0 A
Rated torque 354 ft.lb
Locked rotor torque 310 %
Breakdown torque 330 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 28.7 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 1236 lb
Efficiency
50% 94.6
75% 95.4
100% 95.4
Power factor
50% 0.68
75% 0.78
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole NPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 6002 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 12
Downloads

You may also like

Recently viewed