WEG 10012ST3QIERB444T-W2 W22 IEEE 841 NEMA Premium Efficiency 100 HP 6P 444/5T 3Ph 460 V 60 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 10012ST3QIERB444T-W2

GTIN : 7909018013534

MPN :

Dropship

Price:
Sale price$17,933.00

Description

The W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1200 rpm
Output rating 100 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1185 rpm
Slip 1.25 %
Rated voltage 460 V
Rated current 121 A
L. R. Amperes 714 A
LRC 5.9x(Code G)
No load current 42.0 A
Rated torque 443 ft.lb
Locked rotor torque 220 %
Breakdown torque 229 %
Locked rotor time 36s (cold) 20s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 69.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 94.5
75% 95.0
100% 95.0
Power factor
50% 0.68
75% 0.78
100% 0.82
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 380 V
Rated current 107 A
L. R. Amperes 674 A
LRC 6.3x(Code G)
No load current 41.4 A
Rated torque 400 ft.lb
Locked rotor torque 229 %
Breakdown torque 250 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 93.8
75% 94.3
100% 94.2
Power factor
50% 0.64
75% 0.77
100% 0.83
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 104 A
L. R. Amperes 718 A
LRC 6.9x(Code H)
No load current 44.9 A
Rated torque 398 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 93.8
75% 94.6
100% 94.5
Power factor
50% 0.60
75% 0.74
100% 0.81
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 102 A
L. R. Amperes 755 A
LRC 7.4x(Code J)
No load current 47.7 A
Rated torque 398 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 93.7
75% 94.6
100% 94.6
Power factor
50% 0.57
75% 0.71
100% 0.79
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 145 A
L. R. Amperes 682 A
LRC 4.7x(Code D)
No load current 41.4 A
Rated torque 536 ft.lb
Locked rotor torque 170 %
Breakdown torque 180 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 94.5
75% 94.0
100% 93.6
Power factor
50% 0.74
75% 0.82
100% 0.84
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 400 V
Rated current 139 A
L. R. Amperes 723 A
LRC 5.2x(Code F)
No load current 44.9 A
Rated torque 533 ft.lb
Locked rotor torque 190 %
Breakdown torque 200 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 94.5
75% 94.5
100% 94.0
Power factor
50% 0.71
75% 0.80
100% 0.83
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 135 A
L. R. Amperes 770 A
LRC 5.7x(Code F)
No load current 47.7 A
Rated torque 533 ft.lb
Locked rotor torque 200 %
Breakdown torque 220 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 65.0 dB(A)
Approx. weight³ 1712 lb
Efficiency
50% 94.5
75% 94.5
100% 94.0
Power factor
50% 0.68
75% 0.78
100% 0.82
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System Extended in Stainless Steel, at Drive end and Non-drive end
Main terminal box hole 2xNPT 3"
Terminal Block Without
Shaft Locking Device With
Drain Type T, Threaded
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting According to IEEE-841 (96h)
Joints Seal Molykote
Foot flatness (0.005 pol) 0.127 mm
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Balancing Method 1/2 Key
Drip Cover Without
Connection Cables Quantity 3
Downloads

You may also like

Recently viewed