WEG 10009ET3E445T-W22 W22 NEMA Premium Efficiency 100 HP 8P 444/5T 3Ph 230/460//380 V 60//50 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 10009ET3E445T-W22

GTIN :

MPN :

Dropship

Price:
Sale price$26,988.00

Description

With cast iron frame, flexible mounting, solid and whole feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications.

Standard NEMA MG-1
Frequency 60//50 Hz
Voltage 230/460//380 V
Number of poles 8
Degree of Protection IP55
Synchronous speed 900 rpm
Output rating 100 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 60 Hz
Rated speed 890 rpm
Slip 1.11 %
Rated voltage 230/460 V
Rated current 254/127 A
L. R. Amperes 1524/762 A
LRC 6.0x(Code G)
No load current 112/56.0 A
Rated torque 590 ft.lb
Locked rotor torque 190 %
Breakdown torque 220 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 93.6
75% 94.1
100% 94.1
Power factor
50% 0.63
75% 0.74
100% 0.79
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 118 A
L. R. Amperes 717 A
LRC 6.1x(Code G)
No load current 55.0 A
Rated torque 532 ft.lb
Locked rotor torque 200 %
Breakdown torque 229 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 92.9
75% 93.4
100% 93.2
Power factor
50% 0.59
75% 0.72
100% 0.78
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 116 A
L. R. Amperes 778 A
LRC 6.7x(Code J)
No load current 61.0 A
Rated torque 532 ft.lb
Locked rotor torque 229 %
Breakdown torque 270 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 91.9
75% 93.0
100% 93.2
Power factor
50% 0.55
75% 0.68
100% 0.75
Electric Motors
Frame 444/5T
Output 75 HP (55 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 115 A
L. R. Amperes 806 A
LRC 7.0x(Code J)
No load current 67.0 A
Rated torque 532 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 91.2
75% 92.6
100% 93.1
Power factor
50% 0.51
75% 0.65
100% 0.73
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 735 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 152 A
L. R. Amperes 714 A
LRC 4.7x(Code E)
No load current 55.0 A
Rated torque 714 ft.lb
Locked rotor torque 150 %
Breakdown torque 170 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 93.6
75% 93.0
100% 92.4
Power factor
50% 0.69
75% 0.78
100% 0.81
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 147 A
L. R. Amperes 779 A
LRC 5.3x(Code F)
No load current 61.0 A
Rated torque 710 ft.lb
Locked rotor torque 170 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 93.0
75% 93.0
100% 93.0
Power factor
50% 0.65
75% 0.75
100% 0.79
Electric Motors
Frame 444/5T
Output 100 HP (75 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 740 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 144 A
L. R. Amperes 806 A
LRC 5.6x(Code G)
No load current 67.0 A
Rated torque 710 ft.lb
Locked rotor torque 190 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 87.3 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 1599 lb
Efficiency
50% 92.4
75% 93.0
100% 93.0
Power factor
50% 0.61
75% 0.73
100% 0.78
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xNPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 4140 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 12