WEG 07536EG3E365TS-W22 W22 Super Premium Efficiency 75 HP 2P 364/5TS 3Ph 208-230/460 V 60 Hz IC411 - TEFC - Foot-mounted

WEGSKU: 07536EG3E365TS-W22

GTIN : 7891327885493

MPN :

Dropship

Price:
Sale price$10,000.00

Description

With cast iron frame, flexible mounting, solid feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications. Carry CSA Certified for Division 2 on the Nameplate as standard.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 208-230/460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 75 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 364/5TS
Output 75 HP (55 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3570 rpm
Slip 0.83 %
Rated voltage 230/460 V
Rated current 165/82.6 A
L. R. Amperes 1404/702 A
LRC 8.5x(Code J)
No load current 52.0/26.0 A
Rated torque 110 ft.lb
Locked rotor torque 260 %
Breakdown torque 320 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 8.61 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 79.0 dB(A)
Approx. weight³ 903 lb
Efficiency
50% 93.6
75% 95.0
100% 95.0
Power factor
50% 0.77
75% 0.85
100% 0.88
Electric Motors
Frame 364/5TS
Output 75 HP (55 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 99.4 A
L. R. Amperes 686 A
LRC 6.9x(Code G)
No load current 25.5 A
Rated torque 133 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 8.61 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 903 lb
Efficiency
50% 94.1
75% 94.5
100% 94.5
Power factor
50% 0.82
75% 0.87
100% 0.89
Electric Motors
Frame 364/5TS
Output 75 HP (55 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 400 V
Rated current 93.9 A
L. R. Amperes 704 A
LRC 7.5x(Code H)
No load current 28.0 A
Rated torque 133 ft.lb
Locked rotor torque 220 %
Breakdown torque 280 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 8.61 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 903 lb
Efficiency
50% 94.5
75% 95.0
100% 95.0
Power factor
50% 0.79
75% 0.86
100% 0.89
Electric Motors
Frame 364/5TS
Output 75 HP (55 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2970 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 91.5 A
L. R. Amperes 769 A
LRC 8.4x(Code J)
No load current 29.0 A
Rated torque 133 ft.lb
Locked rotor torque 240 %
Breakdown torque 310 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 8.61 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 903 lb
Efficiency
50% 94.5
75% 95.0
100% 95.0
Power factor
50% 0.76
75% 0.85
100% 0.88
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole NPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 6002 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 12
Downloads

You may also like

Recently viewed