The W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency.
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60 Hz |
| Voltage | 460 V |
| Number of poles | 6 |
| Degree of Protection | IP55 |
| Synchronous speed | 1200 rpm |
| Output rating | 75 HP |
| Mounting | F-1 |
| Flange | Without |
| Terminal box¹ | Left position |
| Enclosure | IC411 - TEFC |
Specifications
460 V 60 Hz 6P 380 V 50 Hz 6P IE3 400 V 50 Hz 6P IE3 415 V 50 Hz 6P IE3 380 V 50 Hz 6P IE1 400 V 50 Hz 6P IE1 415 V 50 Hz 6P IE1Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 75 HP (55 kW) |
| Number of Poles | 6 |
| Frequency | 60 Hz |
| Rated speed | 1184 rpm |
| Slip | 1.33 % |
| Rated voltage | 460 V |
| Rated current | 84.9 A |
| L. R. Amperes | 543 A |
| LRC | 6.4x(Code G) |
| No load current | 30.0 A |
| Rated torque | 333 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 229 % |
| Locked rotor time | 30s (cold) 17s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 68.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 94.1 |
|---|---|
| 75% | 94.5 |
| 100% | 94.5 |
Power factor
| 50% | 0.74 |
|---|---|
| 75% | 0.83 |
| 100% | 0.86 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 988 rpm |
| Slip | 1.20 % |
| Rated voltage | 380 V |
| Rated current | 70.9 A |
| L. R. Amperes | 510 A |
| LRC | 7.2x(Code H) |
| No load current | 29.7 A |
| Rated torque | 266 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 270 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 90.6 |
|---|---|
| 75% | 91.7 |
| 100% | 93.3 |
Power factor
| 50% | 0.66 |
|---|---|
| 75% | 0.79 |
| 100% | 0.85 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 990 rpm |
| Slip | 1.00 % |
| Rated voltage | 400 V |
| Rated current | 69.0 A |
| L. R. Amperes | 545 A |
| LRC | 7.9x(Code J) |
| No load current | 31.8 A |
| Rated torque | 265 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 300 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 91.1 |
|---|---|
| 75% | 92.3 |
| 100% | 93.3 |
Power factor
| 50% | 0.62 |
|---|---|
| 75% | 0.75 |
| 100% | 0.83 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 991 rpm |
| Slip | 0.90 % |
| Rated voltage | 415 V |
| Rated current | 68.1 A |
| L. R. Amperes | 579 A |
| LRC | 8.5x(Code K) |
| No load current | 33.5 A |
| Rated torque | 265 ft.lb |
| Locked rotor torque | 290 % |
| Breakdown torque | 330 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 91.0 |
|---|---|
| 75% | 92.3 |
| 100% | 93.3 |
Power factor
| 50% | 0.60 |
|---|---|
| 75% | 0.74 |
| 100% | 0.81 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 75 HP (55 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 978 rpm |
| Slip | 2.20 % |
| Rated voltage | 380 V |
| Rated current | 104 A |
| L. R. Amperes | 510 A |
| LRC | 4.9x(Code D) |
| No load current | 29.7 A |
| Rated torque | 403 ft.lb |
| Locked rotor torque | 150 % |
| Breakdown torque | 180 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 91.8 |
|---|---|
| 75% | 92.2 |
| 100% | 92.4 |
Power factor
| 50% | 0.79 |
|---|---|
| 75% | 0.86 |
| 100% | 0.87 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 75 HP (55 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 981 rpm |
| Slip | 1.90 % |
| Rated voltage | 400 V |
| Rated current | 98.1 A |
| L. R. Amperes | 540 A |
| LRC | 5.5x(Code E) |
| No load current | 31.8 A |
| Rated torque | 401 ft.lb |
| Locked rotor torque | 170 % |
| Breakdown torque | 200 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 92.4 |
|---|---|
| 75% | 92.8 |
| 100% | 93.0 |
Power factor
| 50% | 0.76 |
|---|---|
| 75% | 0.84 |
| 100% | 0.87 |
Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 75 HP (55 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 983 rpm |
| Slip | 1.70 % |
| Rated voltage | 415 V |
| Rated current | 95.7 A |
| L. R. Amperes | 574 A |
| LRC | 6.0x(Code F) |
| No load current | 33.5 A |
| Rated torque | 401 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 220 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1207 lb |
Efficiency
| 50% | 92.4 |
|---|---|
| 75% | 92.8 |
| 100% | 93.0 |
Power factor
| 50% | 0.74 |
|---|---|
| 75% | 0.83 |
| 100% | 0.86 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | Extended in Stainless Steel, at Drive end and Non-drive end |
| Main terminal box hole | NPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | With |
| Drain | Type T, Threaded |
| Shaft Material | SAE 4140 Carbon Steel |
| Painting | RAL 5009 202E (ISO 12944 - C4) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | According to IEEE-841 (96h) |
| Joints Seal | Molykote |
| Foot flatness | (0.005 pol) 0.127 mm |
| Fan material | Conductive Plastic |
| Bearing cap | Yes- Bearing Cap |
| Bolt Material | Carbon Steel |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 3 |