The W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 60 HP
Mounting F-1
Flange Without
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3550 rpm
Slip 1.39 %
Rated voltage 460 V
Rated current 67.0 A
L. R. Amperes 429 A
LRC 6.4x(Code G)
No load current 15.0 A
Rated torque 88.8 ft.lb
Locked rotor torque 190 %
Breakdown torque 250 %
Locked rotor time 25s (cold) 14s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 79.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 91.7
75% 93.0
100% 93.6
Power factor
50% 0.81
75% 0.88
100% 0.90
Electric Motors
Frame 364/5TS
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 380 V
Rated current 66.6 A
L. R. Amperes 406 A
LRC 6.1x(Code F)
No load current 15.0 A
Rated torque 89.2 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 92.1
75% 92.8
100% 92.8
Power factor
50% 0.81
75% 0.88
100% 0.91
Electric Motors
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2940 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 77.6 A
L. R. Amperes 435 A
LRC 5.6x(Code F)
No load current 16.2 A
Rated torque 107 ft.lb
Locked rotor torque 170 %
Breakdown torque 220 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 92.4
75% 93.0
100% 93.0
Power factor
50% 0.83
75% 0.89
100% 0.90
Electric Motors
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2945 rpm
Slip 1.83 %
Rated voltage 415 V
Rated current 74.8 A
L. R. Amperes 449 A
LRC 6.0x(Code F)
No load current 17.4 A
Rated torque 107 ft.lb
Locked rotor torque 180 %
Breakdown torque 240 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 92.4
75% 93.0
100% 93.0
Power factor
50% 0.81
75% 0.88
100% 0.90
Electric Motors
Frame 364/5TS
Output 60 HP (45 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 380 V
Rated current 81.3 A
L. R. Amperes 407 A
LRC 5.0x(Code D)
No load current 15.0 A
Rated torque 107 ft.lb
Locked rotor torque 150 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)
Moment of inertia (J) 10.6 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 74.0 dB(A)
Approx. weight³ 863 lb
Efficiency
50% 92.4
75% 93.0
100% 92.4
Power factor
50% 0.85
75% 0.90
100% 0.91
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System Extended in Stainless Steel, at Drive end and Non-drive end
Main terminal box hole NPT 3"
Terminal Block Without
Shaft Locking Device Without
Drain Type T, Threaded
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting According to IEEE-841 (96h)
Joints Seal Molykote
Foot flatness (0.005 pol) 0.127 mm
Fan material Conductive Plastic
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 3