WEG 04518ET3Y225S/M-W22 W22 Tru-Metric IE3 60 HP 4P 225S/M 3Ph 460//380-415 V 60 Hz IC411 - TEFC - B3L(E)

WEGSKU: 04518ET3Y225S/M-W22

GTIN : 7891327482555

MPN :

Dropship

Price:
Sale price$7,391.00

Description

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460//380-415 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1800 rpm
Output rating 60 HP
Mounting B3L(E)
Flange Without
Terminal box¹ Right position
Enclosure IC411 - TEFC


Electric Motors
Frame 225S/M
Output 60 HP (45 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1780 rpm
Slip 1.11 %
Rated voltage 460 V
Rated current 69.9 A
L. R. Amperes 573 A
LRC 8.2
No load current 27.0 A
Rated torque 177 ft.lb
Locked rotor torque 290 %
Breakdown torque 310 %
Locked rotor time 43s (cold) 24s (hot)
Moment of inertia (J) 22.6 sq.ft.lb
Design N
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 67.0 dB(A)
Approx. weight³ 951 lb
Efficiency
50% 93.6
75% 94.5
100% 95.0
Power factor
50% 0.69
75% 0.79
100% 0.85
Electric Motors
Frame 225S/M
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 380 V
Rated current 84.4 A
L. R. Amperes 549 A
LRC 6.5
No load current 26.0 A
Rated torque 214 ft.lb
Locked rotor torque 220 %
Breakdown torque 250 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 22.6 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 951 lb
Efficiency
50% 94.0
75% 94.2
100% 94.2
Power factor
50% 0.77
75% 0.82
100% 0.86
Electric Motors
Frame 225S/M
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 81.1 A
L. R. Amperes 568 A
LRC 7.0
No load current 28.0 A
Rated torque 214 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 22.6 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 951 lb
Efficiency
50% 94.0
75% 94.2
100% 94.2
Power factor
50% 0.70
75% 0.80
100% 0.85
Electric Motors
Frame 225S/M
Output 60 HP (45 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 79.1 A
L. R. Amperes 609 A
LRC 7.7
No load current 30.0 A
Rated torque 213 ft.lb
Locked rotor torque 270 %
Breakdown torque 300 %
Locked rotor time 23s (cold) 13s (hot)
Moment of inertia (J) 22.6 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 63.0 dB(A)
Approx. weight³ 951 lb
Efficiency
50% 94.0
75% 94.2
100% 94.2
Power factor
50% 0.67
75% 0.78
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Constant Resin Flow
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Double
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 6
Downloads

You may also like

Recently viewed