Description
With cast iron frame, flexible mounting, solid feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications. Carry CSA Certified for Division 2 on the Nameplate as standard.
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60 Hz |
| Voltage | 208-230/460 V |
| Number of poles | 6 |
| Degree of Protection | IP55 |
| Synchronous speed | 1200 rpm |
| Output rating | 40 HP |
| Mounting | F-1 |
| Flange | Without |
| Terminal box¹ | Left position |
| Enclosure | IC411 - TEFC |
Electric Motors
| Frame | 364/5T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 6 |
| Frequency | 60 Hz |
| Rated speed | 1190 rpm |
| Slip | 0.83 % |
| Rated voltage | 230/460 V |
| Rated current | 97.8/48.9 A |
| L. R. Amperes | 919/460 A |
| LRC | 9.4x(Code L) |
| No load current | 46.0/23.0 A |
| Rated torque | 177 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 320 % |
| Locked rotor time | 55s (cold) 31s (hot) |
| Moment of inertia (J) | 24.2 sq.ft.lb |
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 66.0 dB(A) |
| Approx. weight³ | 935 lb |
Efficiency
| 50% | 93.6 |
|---|---|
| 75% | 94.5 |
| 100% | 95.0 |
Power factor
| 50% | 0.64 |
|---|---|
| 75% | 0.76 |
| 100% | 0.81 |
Electric Motors
| Frame | 364/5T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 380 V |
| Rated current | 58.0 A |
| L. R. Amperes | 429 A |
| LRC | 7.4x(Code H) |
| No load current | 23.0 A |
| Rated torque | 213 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 260 % |
| Locked rotor time | 57s (cold) 32s (hot) |
| Moment of inertia (J) | 24.2 sq.ft.lb |
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 935 lb |
Efficiency
| 50% | 93.0 |
|---|---|
| 75% | 93.6 |
| 100% | 93.6 |
Power factor
| 50% | 0.69 |
|---|---|
| 75% | 0.79 |
| 100% | 0.84 |
Electric Motors
| Frame | 364/5T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 988 rpm |
| Slip | 1.20 % |
| Rated voltage | 400 V |
| Rated current | 56.1 A |
| L. R. Amperes | 443 A |
| LRC | 7.9x(Code J) |
| No load current | 24.0 A |
| Rated torque | 213 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 290 % |
| Locked rotor time | 52s (cold) 29s (hot) |
| Moment of inertia (J) | 24.2 sq.ft.lb |
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 935 lb |
Efficiency
| 50% | 93.6 |
|---|---|
| 75% | 94.1 |
| 100% | 94.1 |
Power factor
| 50% | 0.66 |
|---|---|
| 75% | 0.77 |
| 100% | 0.82 |
Electric Motors
| Frame | 364/5T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 990 rpm |
| Slip | 1.00 % |
| Rated voltage | 415 V |
| Rated current | 54.8 A |
| L. R. Amperes | 460 A |
| LRC | 8.4x(Code K) |
| No load current | 25.0 A |
| Rated torque | 212 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 320 % |
| Locked rotor time | 48s (cold) 27s (hot) |
| Moment of inertia (J) | 24.2 sq.ft.lb |
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 935 lb |
Efficiency
| 50% | 93.6 |
|---|---|
| 75% | 94.1 |
| 100% | 94.1 |
Power factor
| 50% | 0.63 |
|---|---|
| 75% | 0.75 |
| 100% | 0.81 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | NPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 6002 203A (ISO 12944 - C2) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 12 |