WEG 01518ET3E254HP-W22 W22 P Base NEMA Premium Efficiency 15 HP 4P 254HP 3Ph 230/460//380 V 60//50 Hz IC411 - TEFC - Footless

WEGSKU: 01518ET3E254HP-W22

GTIN : 7909265382056

MPN :

Dropship

Price:
Sale price$2,463.00

Description

Line of vertical motors with flange type P. For application on irrigation pumps, water treatment, petrochemical industry, among others, in environments with dust and humidity demanding high torque.

Standard NEMA MG-1
Frequency 60//50 Hz
Voltage 230/460//380 V
Number of poles 4
Degree of Protection IP55
Synchronous speed 1800 rpm
Output rating 15 HP
Mounting W-6
Flange P
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 254HP
Output 15 HP (11 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1768 rpm
Slip 1.78 %
Rated voltage 230/460 V
Rated current 36.0/18.0 A
L. R. Amperes 230/115 A
LRC 6.4x(Code G)
No load current 14.0/7.00 A
Rated torque 44.6 ft.lb
Locked rotor torque 240 %
Breakdown torque 260 %
Locked rotor time 55s (cold) 31s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 64.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 91.0
75% 91.7
100% 92.4
Power factor
50% 0.68
75% 0.78
100% 0.83
Electric Motors
Frame 254HP
Output 10 HP (7.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1475 rpm
Slip 1.67 %
Rated voltage 380 V
Rated current 15.2 A
L. R. Amperes 109 A
LRC 7.2x(Code J)
No load current 6.70 A
Rated torque 35.6 ft.lb
Locked rotor torque 250 %
Breakdown torque 300 %
Locked rotor time 72s (cold) 40s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 88.8
75% 90.3
100% 90.4
Power factor
50% 0.65
75% 0.77
100% 0.83
Electric Motors
Frame 254HP
Output 10 HP (7.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 400 V
Rated current 14.8 A
L. R. Amperes 115 A
LRC 7.8x(Code J)
No load current 7.10 A
Rated torque 35.5 ft.lb
Locked rotor torque 280 %
Breakdown torque 340 %
Locked rotor time 63s (cold) 35s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 88.6
75% 90.3
100% 90.6
Power factor
50% 0.62
75% 0.74
100% 0.81
Electric Motors
Frame 254HP
Output 10 HP (7.5 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 415 V
Rated current 14.5 A
L. R. Amperes 120 A
LRC 8.3x(Code K)
No load current 7.40 A
Rated torque 35.5 ft.lb
Locked rotor torque 310 %
Breakdown torque 370 %
Locked rotor time 57s (cold) 32s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 88.3
75% 90.3
100% 90.8
Power factor
50% 0.59
75% 0.72
100% 0.79
Electric Motors
Frame 254HP
Output 15 HP (11 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1455 rpm
Slip 3.00 %
Rated voltage 380 V
Rated current 21.5 A
L. R. Amperes 105 A
LRC 4.9x(Code E)
No load current 7.10 A
Rated torque 54.1 ft.lb
Locked rotor torque 160 %
Breakdown torque 200 %
Locked rotor time 41s (cold) 23s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 91.0
75% 90.2
100% 90.2
Power factor
50% 0.74
75% 0.82
100% 0.86
Electric Motors
Frame 254HP
Output 15 HP (11 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 400 V
Rated current 20.5 A
L. R. Amperes 111 A
LRC 5.4x(Code F)
No load current 7.60 A
Rated torque 54.0 ft.lb
Locked rotor torque 200 %
Breakdown torque 220 %
Locked rotor time 41s (cold) 23s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 91.0
75% 91.0
100% 91.0
Power factor
50% 0.71
75% 0.80
100% 0.85
Electric Motors
Frame 254HP
Output 15 HP (11 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1465 rpm
Slip 2.33 %
Rated voltage 415 V
Rated current 20.0 A
L. R. Amperes 118 A
LRC 5.9x(Code G)
No load current 7.40 A
Rated torque 53.8 ft.lb
Locked rotor torque 210 %
Breakdown torque 240 %
Locked rotor time 37s (cold) 21s (hot)
Moment of inertia (J) 2.62 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 61.0 dB(A)
Approx. weight³ 303 lb
Efficiency
50% 91.0
75% 91.0
100% 91.0
Power factor
50% 0.69
75% 0.79
100% 0.84
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole NPT 1 1/2"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Single
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover With
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 12
Downloads