With cast iron frame, flexible mounting, solid and whole feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications.

Standard NEMA MG-1
Frequency 60 Hz
Voltage 460//380-415 V
Number of poles 8
Degree of Protection IP55
Synchronous speed 900 rpm
Output rating 20 HP
Mounting B3L(E)
Flange Without
Terminal box¹ Right position
Enclosure IC411 - TEFC


Electric Motors
Frame 200L
Output 20 HP (15 kW)
Number of Poles 8
Frequency 60 Hz
Rated speed 885 rpm
Slip 1.67 %
Rated voltage 460 V
Rated current 28.0 A
L. R. Amperes 146 A
LRC 5.2
No load current 15.3 A
Rated torque 119 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 79s (cold) 44s (hot)
Moment of inertia (J) 10.8 sq.ft.lb
Design N
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 550 lb
Efficiency
50% 89.5
75% 91.0
100% 91.0
Power factor
50% 0.55
75% 0.67
100% 0.74
Electric Motors
Frame 200L
Output 20 HP (15 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 730 rpm
Slip 2.67 %
Rated voltage 380 V
Rated current 33.0 A
L. R. Amperes 162 A
LRC 4.9
No load current 14.7 A
Rated torque 144 ft.lb
Locked rotor torque 170 %
Breakdown torque 190 %
Locked rotor time 61s (cold) 34s (hot)
Moment of inertia (J) 10.8 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 550 lb
Efficiency
50% 90.5
75% 91.0
100% 91.0
Power factor
50% 0.60
75% 0.71
100% 0.76
Electric Motors
Frame 200L
Output 20 HP (15 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 730 rpm
Slip 2.67 %
Rated voltage 400 V
Rated current 32.0 A
L. R. Amperes 157 A
LRC 4.9
No load current 16.0 A
Rated torque 144 ft.lb
Locked rotor torque 190 %
Breakdown torque 210 %
Locked rotor time 61s (cold) 34s (hot)
Moment of inertia (J) 10.8 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 550 lb
Efficiency
50% 90.0
75% 91.0
100% 91.4
Power factor
50% 0.56
75% 0.68
100% 0.74
Electric Motors
Frame 200L
Output 20 HP (15 kW)
Number of Poles 8
Frequency 50 Hz
Rated speed 730 rpm
Slip 2.67 %
Rated voltage 415 V
Rated current 31.7 A
L. R. Amperes 155 A
LRC 4.9
No load current 17.2 A
Rated torque 144 ft.lb
Locked rotor torque 210 %
Breakdown torque 229 %
Locked rotor time 61s (cold) 34s (hot)
Moment of inertia (J) 10.8 sq.ft.lb
Design N
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle S1
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting B3L(E)
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 550 lb
Efficiency
50% 89.4
75% 90.8
100% 91.5
Power factor
50% 0.53
75% 0.65
100% 0.72
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Regreasing System At Drive end and Non-drive end
Main terminal box hole 2xM50x1,5
Terminal Block BMC - 6 pins
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 203A (ISO 12944 - C2)
Grounding Lugs Single
Fan Cover material Cast Iron
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Balancing Method 1/2 Key
Drip Cover Without
Overload protector (phenolic) Without overload protector