WEG 00512ET3ECT215T-W22 W22 Cooling Tower NEMA Premium Efficiency 5 HP 6P 213/5T 3Ph 230/460//380 V 60//50 Hz IC411 - TEFC - Foot-mounted


Price:
Sale price$1,168.09

Description

These TEFC and TEAO motors are built according to NEMA standards and designed for operation in 100% humidity and the most corrosive environments.

Standard NEMA MG-1
Frequency 60//50 Hz
Voltage 230/460//380 V
Number of poles 6
Degree of Protection IP55
Synchronous speed 1200 rpm
Output rating 5 HP
Mounting F-2
Flange Without
Terminal box¹ Right position
Enclosure IC411 - TEFC


Electric Motors
Frame 213/5T
Output 5 HP (3.7 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1170 rpm
Slip 2.50 %
Rated voltage 230/460 V
Rated current 13.7/6.83 A
L. R. Amperes 92.9/46.4 A
LRC 6.8x(Code J)
No load current 6.90/3.45 A
Rated torque 22.4 ft.lb
Locked rotor torque 170 %
Breakdown torque 260 %
Locked rotor time 102s (cold) 57s (hot)
Moment of inertia (J) 1.47 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-2
Rotation¹ Both (CW and CCW)
Noise level² 55.0 dB(A)
Approx. weight³ 175 lb
Efficiency
50% 88.5
75% 89.5
100% 89.5
Power factor
50% 0.58
75% 0.70
100% 0.76
Electric Motors
Frame 213/5T
Output 5 HP (3.7 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 960 rpm
Slip 4.00 %
Rated voltage 380/380 V
Rated current 8.10/8.10 A
L. R. Amperes 44.5/44.5 A
LRC 5.5x(Code G)
No load current 3.41/3.41 A
Rated torque 27.4 ft.lb
Locked rotor torque 140 %
Breakdown torque 200 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 1.47 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-2
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 175 lb
Efficiency
50% 88.5
75% 88.5
100% 86.8
Power factor
50% 0.65
75% 0.76
100% 0.80
Electric Motors
Frame 213/5T
Output 5 HP (3.7 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 965 rpm
Slip 3.50 %
Rated voltage 400 V
Rated current 7.82 A
L. R. Amperes 47.7 A
LRC 6.1x(Code H)
No load current 3.68 A
Rated torque 27.2 ft.lb
Locked rotor torque 160 %
Breakdown torque 229 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 1.47 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-2
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 175 lb
Efficiency
50% 88.5
75% 88.5
100% 87.5
Power factor
50% 0.61
75% 0.73
100% 0.78
Electric Motors
Frame 213/5T
Output 5 HP (3.7 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 415 V
Rated current 7.55 A
L. R. Amperes 49.1 A
LRC 6.5x(Code H)
No load current 3.90 A
Rated torque 27.1 ft.lb
Locked rotor torque 190 %
Breakdown torque 250 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 1.47 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-2
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 175 lb
Efficiency
50% 87.5
75% 88.5
100% 88.5
Power factor
50% 0.58
75% 0.71
100% 0.77
Features
Frame Material Cast Iron
Impregnation Method Double impregnation polyester
Space Heater Voltage 110-127/200-240 V
Main terminal box hole NPT 1"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 202E (ISO 12944 - C4)
Grounding Lugs Single
Fan Cover material Steel
Tropicalized Painting Complete (200h)
Joints Seal Permatex
Fan material Plastic
Bearing cap No-Without Bearing Cap
Drip Cover Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 9
Downloads

You may also like

Recently viewed