WEG 00336ET3ER182TC-W22 W22 NEMA Premium Efficiency 3 HP 2P 182TC 3Ph 230/460//380 V 60//50 Hz IC411 - TEFC - Footless

WEGSKU: 00336ET3ER182TC-W22

Drop-Ship

Price:
Sale price$636.03

Description

With cast iron frame, flexible mounting, solid and whole feet, and lower noise levels and operating temperatures, the W22 motors are perfectly suitable for a great variety of industrial applications.

Standard NEMA MG-1
Frequency 60//50 Hz
Voltage 230/460//380 V
Number of poles 2
Degree of Protection IP55
Synchronous speed 3600 rpm
Output rating 3 HP
Mounting W-6
Flange C
Terminal box¹ Left position
Enclosure IC411 - TEFC


Electric Motors
Frame 182TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3510 rpm
Slip 2.50 %
Rated voltage 230/460 V
Rated current 7.26/3.63 A
L. R. Amperes 62.4/31.2 A
LRC 8.6x(Code K)
No load current 2.60/1.30 A
Rated torque 4.49 ft.lb
Locked rotor torque 250 %
Breakdown torque 380 %
Locked rotor time 73s (cold) 41s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 82.5
75% 86.5
100% 86.5
Power factor
50% 0.75
75% 0.84
100% 0.88
Electric Motors
Frame 182TC
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2930 rpm
Slip 2.33 %
Rated voltage 380 V
Rated current 3.09 A
L. R. Amperes 29.7 A
LRC 9.6x(Code L)
No load current 1.25 A
Rated torque 3.58 ft.lb
Locked rotor torque 300 %
Breakdown torque 430 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 81.0
75% 84.5
100% 85.8
Power factor
50% 0.68
75% 0.79
100% 0.86
Electric Motors
Frame 182TC
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 400 V
Rated current 3.00 A
L. R. Amperes 32.1 A
LRC 10.7x(Code M)
No load current 1.35 A
Rated torque 3.58 ft.lb
Locked rotor torque 340 %
Breakdown torque 480 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 80.6
75% 84.5
100% 85.8
Power factor
50% 0.65
75% 0.77
100% 0.84
Electric Motors
Frame 182TC
Output 2 HP (1.5 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2940 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 2.96 A
L. R. Amperes 32.9 A
LRC 11.1x(Code N)
No load current 1.40 A
Rated torque 3.57 ft.lb
Locked rotor torque 370 %
Breakdown torque 520 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 79.7
75% 84.1
100% 85.9
Power factor
50% 0.63
75% 0.75
100% 0.82
Electric Motors
Frame 182TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2880 rpm
Slip 4.00 %
Rated voltage 380 V
Rated current 4.34 A
L. R. Amperes 29.5 A
LRC 6.8x(Code H)
No load current 1.25 A
Rated torque 5.47 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 84.0
75% 86.5
100% 85.5
Power factor
50% 0.80
75% 0.87
100% 0.90
Electric Motors
Frame 182TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2890 rpm
Slip 3.67 %
Rated voltage 400 V
Rated current 4.17 A
L. R. Amperes 31.7 A
LRC 7.6x(Code J)
No load current 1.35 A
Rated torque 5.45 ft.lb
Locked rotor torque 240 %
Breakdown torque 320 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 84.0
75% 86.5
100% 85.5
Power factor
50% 0.77
75% 0.86
100% 0.89
Electric Motors
Frame 182TC
Output 3 HP (2.2 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2900 rpm
Slip 3.33 %
Rated voltage 415 V
Rated current 4.07 A
L. R. Amperes 33.0 A
LRC 8.1x(Code J)
No load current 1.40 A
Rated torque 5.43 ft.lb
Locked rotor torque 260 %
Breakdown torque 350 %
Locked rotor time 54s (cold) 30s (hot)
Moment of inertia (J) 0.1889 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting W-6
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 86.0 lb
Efficiency
50% 84.0
75% 86.5
100% 85.5
Power factor
50% 0.75
75% 0.84
100% 0.88
Features
Frame Material Cast Iron
Impregnation Method Dip and Bake Polyester
Main terminal box hole NPT 1"
Terminal Block Without
Shaft Locking Device Without
Drain Rubber, automatic
Shaft Material SAE 1040/45 Carbon Steel
Painting RAL 5009 207A (ISO 12944 - C2)
Grounding Lugs Single
Fan Cover material Steel
Tropicalized Painting Without
Fan material Plastic
Bearing cap Yes- Bearing Cap
Drip Cover With
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 9
Downloads