Description
The W01 motor is the perfect option for applications that require robustness, low weight and high performance in a single product. The W01 Rolled Steel platform has good thermal performance and easy installation and maintenance.
Standard | NEMA MG-1 |
---|---|
Frequency | 60//50 Hz |
Voltage | 230/460//190-220/380-415 V |
Number of poles | 2 |
Degree of Protection | IP55 |
Synchronous speed | 3600 rpm |
Output rating | 3 HP |
Mounting | F-1 |
Flange | C |
Terminal box¹ | Left position |
Enclosure | IC411 - TEFC |
Electric Motors
Frame | 182/4JM |
---|---|
Output | 3 HP (2.2 kW) |
Number of Poles | 2 |
Frequency | 60 Hz |
Rated speed | 3510 rpm |
Slip | 2.50 % |
Rated voltage | 230/460 V |
Rated current | 7.60/3.80 A |
L. R. Amperes | 63.1/31.5 A |
LRC | 8.3x(Code K) |
No load current | 3.48/1.74 A |
Rated torque | 4.49 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 350 % |
Locked rotor time | 48s (cold) 27s (hot) |
Moment of inertia (J) | 0.1391 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 68.0 dB(A) |
Approx. weight³ | 59.5 lb |
Efficiency
50% | 82.5 |
---|---|
75% | 85.5 |
100% | 85.5 |
Power factor
50% | 0.69 |
---|---|
75% | 0.80 |
100% | 0.85 |
Electric Motors
Frame | 182/4JM |
---|---|
Output | 3 HP (2.2 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2885 rpm |
Slip | 3.83 % |
Rated voltage | 190-220/380 V |
Rated current | 8.82-7.62/4.41 A |
L. R. Amperes | 60.9-52.6/30.4 A |
LRC | 6.9x(Code H) |
No load current | 3.43-2.97/1.72 A |
Rated torque | 5.46 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 280 % |
Locked rotor time | 0s (cold) 0s (hot) |
Moment of inertia (J) | 0.1391 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 65.0 dB(A) |
Approx. weight³ | 59.5 lb |
Efficiency
50% | 85.2 |
---|---|
75% | 86.1 |
100% | 85.1 |
Power factor
50% | 0.75 |
---|---|
75% | 0.85 |
100% | 0.89 |
Electric Motors
Frame | 182/4JM |
---|---|
Output | 3 HP (2.2 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2905 rpm |
Slip | 3.17 % |
Rated voltage | 415 V |
Rated current | 4.13 A |
L. R. Amperes | 33.5 A |
LRC | 8.1x(Code K) |
No load current | 1.97 A |
Rated torque | 5.42 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 340 % |
Locked rotor time | 0s (cold) 0s (hot) |
Moment of inertia (J) | 0.1391 sq.ft.lb |
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 65.0 dB(A) |
Approx. weight³ | 59.5 lb |
Efficiency
50% | 84.5 |
---|---|
75% | 86.3 |
100% | 86.1 |
Power factor
50% | 0.68 |
---|---|
75% | 0.80 |
100% | 0.86 |
Features
Frame Material | Rolled Steel |
---|---|
Impregnation Method | Dip and Bake Polyester |
Main terminal box hole | 1.118" |
Terminal Block | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | Munsell N 1 - Matte 207N (ISO 12944 - C2) |
Grounding Lugs | Single |
Fan Cover material | Steel |
Tropicalized Painting | Without |
Fan material | Plastic |
Bearing cap | Yes- Bearing Cap |
Bolt Material | Carbon Steel |
Balancing Method | 1/2 Key |
Drip Cover | Without |
Resilient Base | Without |
Overload protector (phenolic) | Without overload protector |
Connection Cables Quantity | 9 |