Description
Motor with steel plate frame, for general use, developed to meet different applications with maximum performance and economy.
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60 Hz |
| Voltage | 230/460 V |
| Number of poles | 4 |
| Degree of Protection | IP21 |
| Synchronous speed | 1800 rpm |
| Output rating | 3 HP |
| Mounting | F-2 |
| Flange | Without |
| Terminal box¹ | Right position |
| Enclosure | IC01 - ODP |
Electric Motors
| Frame | 182T |
|---|---|
| Output | 3 HP (2.2 kW) |
| Number of Poles | 4 |
| Frequency | 60 Hz |
| Rated speed | 1760 rpm |
| Slip | 2.22 % |
| Rated voltage | 230/460 V |
| Rated current | 8.12/4.06 A |
| L. R. Amperes | 65.8/32.9 A |
| LRC | 8.1x(Code K) |
| No load current | 4.74/2.37 A |
| Rated torque | 8.95 ft.lb |
| Locked rotor torque | 240 % |
| Breakdown torque | 300 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 0.2541 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP21 |
| Enclosure | IC01 - ODP |
| Mounting | F-2 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 53.0 dB(A) |
| Approx. weight³ | 61.4 lb |
Efficiency
| 50% | 85.5 |
|---|---|
| 75% | 88.5 |
| 100% | 89.5 |
Power factor
| 50% | 0.54 |
|---|---|
| 75% | 0.68 |
| 100% | 0.76 |
Electric Motors
| Frame | 182T |
|---|---|
| Output | 3 HP (2.2 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1450 rpm |
| Slip | 3.33 % |
| Rated voltage | 380 V |
| Rated current | 4.72 A |
| L. R. Amperes | 28.8 A |
| LRC | 6.1x(Code H) |
| No load current | 2.15 A |
| Rated torque | 10.9 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 280 % |
| Locked rotor time | 34s (cold) 19s (hot) |
| Moment of inertia (J) | 0.2541 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP21 |
| Enclosure | IC01 - ODP |
| Mounting | F-2 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 53.0 dB(A) |
| Approx. weight³ | 61.4 lb |
Efficiency
| 50% | 85.5 |
|---|---|
| 75% | 86.5 |
| 100% | 87.5 |
Power factor
| 50% | 0.63 |
|---|---|
| 75% | 0.75 |
| 100% | 0.81 |
Electric Motors
| Frame | 182T |
|---|---|
| Output | 3 HP (2.2 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1450 rpm |
| Slip | 3.33 % |
| Rated voltage | 400 V |
| Rated current | 4.65 A |
| L. R. Amperes | 30.2 A |
| LRC | 6.5x(Code H) |
| No load current | 2.40 A |
| Rated torque | 10.9 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 310 % |
| Locked rotor time | 30s (cold) 17s (hot) |
| Moment of inertia (J) | 0.2541 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP21 |
| Enclosure | IC01 - ODP |
| Mounting | F-2 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 53.0 dB(A) |
| Approx. weight³ | 61.4 lb |
Efficiency
| 50% | 85.5 |
|---|---|
| 75% | 86.5 |
| 100% | 87.5 |
Power factor
| 50% | 0.58 |
|---|---|
| 75% | 0.71 |
| 100% | 0.78 |
Electric Motors
| Frame | 182T |
|---|---|
| Output | 3 HP (2.2 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1455 rpm |
| Slip | 3.00 % |
| Rated voltage | 415 V |
| Rated current | 4.66 A |
| L. R. Amperes | 32.2 A |
| LRC | 6.9x(Code J) |
| No load current | 2.65 A |
| Rated torque | 10.8 ft.lb |
| Locked rotor torque | 250 % |
| Breakdown torque | 340 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 0.2541 sq.ft.lb |
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP21 |
| Enclosure | IC01 - ODP |
| Mounting | F-2 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 53.0 dB(A) |
| Approx. weight³ | 61.4 lb |
Efficiency
| 50% | 85.5 |
|---|---|
| 75% | 86.5 |
| 100% | 87.5 |
Power factor
| 50% | 0.53 |
|---|---|
| 75% | 0.67 |
| 100% | 0.75 |
Features
| Frame Material | Rolled Steel |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Main terminal box hole | NPT 3/4" |
| Terminal Block | Without |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 5009 207A (ISO 12944 - C2) |
| Grounding Lugs | Single |
| Fan Cover material | Without Fan Cover |
| Tropicalized Painting | Without |
| Fan material | Without fan |
| Bearing cap | No-Without Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Resilient Base | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 9 |