WEG 00318OT3E182JP-S Rolled Steel JP Pump NEMA Premium Efficiency 3 HP 4P 182/4JP 3Ph 230/460//190-220/380-415 V 60 Hz IC01 - ODP - Foot-mounted


Price:
Sale price$512.05

Description

Standard NEMA MG-1
Frequency 60//50 Hz
Voltage 230/460//190-220/380-415 V
Number of poles 4
Synchronous speed 1800 rpm
Output rating 3 HP
Mounting F-1
Flange C
Terminal box¹ Left position
Enclosure IC01 - ODP


Electric Motors
Frame 182/4JP
Output 3 HP (2.2 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1765 rpm
Slip 1.94 %
Rated voltage 230/460 V
Rated current 7.72/3.86 A
L. R. Amperes 64.8/32.4 A
LRC 8.4x(Code K)
No load current 4.14/2.07 A
Rated torque 8.93 ft.lb
Locked rotor torque 220 %
Breakdown torque 330 %
Locked rotor time 27s (cold) 15s (hot)
Moment of inertia (J) 0.3092 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Enclosure IC01 - ODP
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 55.0 dB(A)
Approx. weight³ 75.4 lb
Efficiency
50% 87.5
75% 88.5
100% 89.5
Power factor
50% 0.60
75% 0.73
100% 0.80
Electric Motors
Frame 182/4JP
Output 3 HP (2.2 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1460 rpm
Slip 2.67 %
Rated voltage 190-220/380 V
Rated current 9.08-7.84/4.54 A
L. R. Amperes 58.1-50.2/29.1 A
LRC 6.4x(Code H)
No load current 4.08-3.52/2.04 A
Rated torque 10.8 ft.lb
Locked rotor torque 150 %
Breakdown torque 240 %
Locked rotor time 0s (cold) 0s (hot)
Moment of inertia (J) 0.3092 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Enclosure IC01 - ODP
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 75.4 lb
Efficiency
50% 86.0
75% 86.5
100% 86.7
Power factor
50% 0.68
75% 0.79
100% 0.85
Electric Motors
Frame 182/4JP
Output 3 HP (2.2 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1470 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 4.33 A
L. R. Amperes 32.5 A
LRC 7.5x(Code J)
No load current 2.37 A
Rated torque 10.7 ft.lb
Locked rotor torque 180 %
Breakdown torque 300 %
Locked rotor time 0s (cold) 0s (hot)
Moment of inertia (J) 0.3092 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Enclosure IC01 - ODP
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 75.4 lb
Efficiency
50% 86.8
75% 87.8
100% 87.2
Power factor
50% 0.60
75% 0.73
100% 0.81
Features
Frame Material Rolled Steel
Impregnation Method Dip and Bake Polyester
Main terminal box hole 1.118"
Terminal Block Without
Shaft Material SAE 1040/45 Carbon Steel
Painting Munsell N 1 - Matte 207N (ISO 12944 - C2)
Grounding Lugs Single
Fan Cover material Without Fan Cover
Tropicalized Painting Without
Fan material Without fan
Bearing cap Yes- Bearing Cap
Bolt Material Carbon Steel
Balancing Method 1/2 Key
Drip Cover Without
Resilient Base Without
Overload protector (phenolic) Without overload protector
Connection Cables Quantity 9
Downloads