Description
- Definite Purpose
- Three Phase Unimount®
- Totally Enclosed Fan Cooled (TEFC)
- Multi-Speed
- Constant Torque 1800/900 RPM One Winding
Specifications
| Model_Number | C732 |
|---|---|
| PRODUCT NAME | 3 HP - TE - 1720 |
| PHASETYPE | 3_PHASE |
| MOTOR ENCLOSURE | TE |
| HORSEPOWER | 3 |
| HORSEPOWER 2 | 1.5 |
| KILOWATTS | 2.2 |
| POLES | 4 |
| POLES 2 | 8 |
| NUMBER SPEEDS | 2 |
| RPM | 1720 |
| RPM 2 | 865 |
| HERTZ | 60 |
| VOLTS PRIMARY | 460 |
| VOLTS | 460 |
| FRME | 184 |
| SHAFT CODE | T |
| MOUNTING | HORZ-FOOTED |
| ASSEMBLY POSITION | F1 |
| MOTOR TYPE | UT |
| OPPOSITE END BEARING | 6205-2Z-J/C3 |
| SHAFT END BEARING | 6206-2Z-J/C3 |
| AMBIENT | 40 |
| ROTATION | DUAL |
| SERVICE FACTOR | 1.15 |
| STARTCAPMFD | N\A |
| SHIPPING WEIGHT | 67 |
| BREAKDOWN TORQUE | 289 |
| BREAKDOWN TORQUE UOM | PERCENT OF FLT |
| LOCKED ROTOR TORQUE | 216 |
| LOCKED ROTOR TORQUE UOM | PERCENT OF FLT |
| INSULATION CLASS | F |
| KVA CODE LETTER | H |
| LOCKED ROTOR AMPS | 25.6 |
| NEMA NOMINAL EFFICIENCY | 78.5 |
| FULL LOAD AMPS PRIMARY | 4.1 |
| SERVICE FACTOR AMPS PRIMARY | 4.8 |